Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rinnai Error Code COdE: Access code entry (Boiler)

Updated · by Aurora Star Tech Inc.

Rinnai error code COdE on a boiler means: Access code entry. It is also called Rinnai diagnostic code COdE.

Low severityBoilerE-Combi (E50CRN · E75CRN/E75CRP · E110CRN/E110CRP)

Homeowner? What Rinnai code COdE means for you

Usually minor Your boiler is reporting: Access code entry. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code COdE mean?

Shown after holding Mode 5 s; select C123 with + / - and confirm with Store to open installer level.

Applies to: E50CRN; E75CRN; E75CRP; E110CRN; E110CRP

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Rinnai Boiler codes

CodeMeaning
A XXDe-aeration running
Block 01External safety contact open
Block 05Outdoor sensor not connected
Block 60Wrong minimum/maximum power parameter
Block 67Supply/return sensor difference with burner off
Block 85No water flow detected
CopyFactory settings restored
E00Poor flame formation (flame sensed with burner off)
E02No flame formation (ignition failure)
E04Voltage interruption / error read-out interrupted
E05Adjustment error (listed in short reference)
E12High limit stat open

All Rinnai Boiler error codes →

Rinnai code COdE: homeowner questions

What does Rinnai code COdE mean?

Access code entry. Shown after holding Mode 5 s; select C123 with + / - and confirm with Store to open installer level.

Is it safe to keep using my boiler with code COdE?

Usually yes. Code COdE is normally minor, but if it keeps coming back have it checked.

Can I reset Rinnai code COdE myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code COdE comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code COdE near me?

Aurora Star Tech Inc. repairs Rinnai boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Rinnai E-Combi Series Installation & Servicing Instructions (8U516009 V0116), p.56 (10.1). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977