Rinnai Error Code 310: Freeze protection thermistor fault (Boiler)

Updated · by Aurora Star Tech Inc.

Rinnai error code 310 on a boiler means: Freeze protection thermistor fault. It is also called Rinnai diagnostic code 310.

Medium severityBoilerAlso Combi BoilerI-Series Plus 150K and smaller · I-Series Plus 175K and higher

Homeowner? What Rinnai code 310 means for you

Check, then call Your boiler is reporting: Freeze protection thermistor fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code 310 mean?

Fault detected in the freeze protection thermistor circuit.

Applies to: I-Series Plus boilers — 150K BTU and smaller and 175K BTU and higher (Combi and Solo)

Common causes of Rinnai code 310

  • Loose, broken or damaged thermistor wiring/connectors
  • Thermistor unplugged (reads -40)
  • Damaged or failed thermistor

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rinnai models that use code 310

IP060SIP090SIP120SIP150SIP175SIP199S

Other Rinnai Boiler codes

CodeMeaning
180Gas valve air/fuel adjustment limit reached
190Electrical grounding / short in DC circuit
210Data transfer error
220Gas valve position not detected (reed switch)
250Condensate pump switch tripped (accessory)
303Secondary system thermistor fault
353CH supply thermistor fault
363CH return thermistor fault
371Indirect tank thermistor fault
380Exhaust thermistor fault
393Outdoor temperature sensor fault
400Water pressure sensor communication fault

All Rinnai Boiler error codes →

Rinnai code 310: homeowner questions

What does Rinnai code 310 mean?

Freeze protection thermistor fault. Fault detected in the freeze protection thermistor circuit.

Is it safe to keep using my boiler with code 310?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Rinnai code 310 myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code 310 comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code 310 near me?

Aurora Star Tech Inc. repairs Rinnai boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Rinnai Troubleshooting I-Series Plus Boiler Diagnostic Codes (800000375), p.17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.