Rinnai Boiler: DHW Recirculation Does Not Begin (Combi Only)
DHW Recirculation Does Not Begin (Combi Only) on a Rinnai boiler: Recirculation pump does not start.
Applies to: I-Series Plus combi boiler
Common causes of dhw recirculation does not begin (combi only)
- Pump not on DHW_Pump terminal
- Parameter 09 off
- Recirculation plumbing type wrong (parameter 12)
- Timer relay input wrong (parameter 13)
- External timer wiring wrong or timer off
- Recirculation OFF interval after use
How to fix dhw recirculation does not begin (combi only): step by step
- Confirm the recirculation pump is connected to the DHW_Pump terminal.
- Confirm parameter 09 is ON.
- Confirm the plumbing type is set per parameter 12.
- Confirm the timer relay input is set per parameter 13.
- Confirm wiring to the external timer is correct.
- Confirm the external timer is ON, if used.
- Wait out the recirculation OFF interval after use if it is normal.
If the unit shows an error code, look it up: Rinnai Boiler codes
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 117. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.