Updated · by Aurora Star Tech Inc.

Enter parameter settings mode on a Rinnai boiler: Parameter settings are changed from the PC board, not the controller display buttons. Use the left PC board button to enter and exit.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: I-Series Plus condensing combi boiler parameter settings

How to fix enter parameter settings mode: step by step

  1. Remove the boiler front panel by taking out the two securing screws.
  2. Locate the PC board on the lower left side of the unit.
  3. Press and hold the left PC board button for five seconds. Parameter 00-A appears on the display.
  4. Use the Up or Down arrows to select a parameter number, then press Select.
  5. Use the Up or Down arrows to change the setting for that parameter, then press Select.
  6. To exit parameter settings and return to normal operation, press the PC board button.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

More access & passwords tips for boiler

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 89. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.