Rinnai Boiler: Power supply and grounding requirements
Power supply and grounding requirements on a Rinnai boiler: Power supply, grounding and disconnect rules for the boiler. The boiler needs 120 VAC, 60 Hz from a grounded circuit. Do not use extension cords or adapter plugs. Gas or water piping must not be used as the ground.
Applies to: I-Series Plus condensing combi boilers
How to fix power supply and grounding requirements: step by step
- Use a grounded 120 VAC, 60 Hz circuit with a three-prong receptacle.
- Use the 5 ft (1.5 m) power cord supplied with the boiler. Do not use an extension cord or adapter.
- Do not cut or remove the ground pin on the plug.
- Use the ground locations provided inside the boiler.
- Remove the plug before any internal repairs, installation work, or changes to terminal wiring.
- Label all wires before disconnecting them for control service.
- Do not change the boiler wiring.
- Install a manual remote shutoff switch outside each boiler room door. Protect it from tampering.
- Verify correct operation after any service.
If the unit shows an error code, look it up: Rinnai Boiler codes
Source: Rinnai I-Series Plus IP060160C installation manual, p. 66. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.