Rinnai Boiler: Change altitude setting on the PC board

Updated · by Aurora Star Tech Inc.

Change altitude setting on the PC board on a Rinnai boiler: Sets Parameter A3 for high altitude. Gas pressure does not need to be changed for high altitude when this parameter is used.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: I-Series Plus PC board, Parameter A3

How to fix change altitude setting on the pc board: step by step

  1. Remove the front panel by taking out the two screws that hold it.
  2. Locate the PC board on the lower left side of the unit.
  3. Locate the PC board buttons.
  4. Press the SW1 left button.
  5. Scroll to Parameter A3.
  6. Set Parameter A3 to the letter that matches the site altitude in the altitude table.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

More commissioning tips for boiler

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 84. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.