Rinnai Error Code dES: Descaling (automated flush) mode (Boiler)

Updated · by Aurora Star Tech Inc.

Rinnai error code dES on a boiler means: Descaling (automated flush) mode. It is also called Rinnai diagnostic code dES.

Low severityBoilerI-Series Plus

Homeowner? What Rinnai code dES means for you

Usually minor Your boiler is reporting: Descaling (automated flush) mode. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code dES mean?

Shown on the controller when the descaling mode is selected with the SW3 button on the PC board and the up or down arrow.

Applies to: All I-Series Plus condensing combi boilers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Rinnai Boiler codes

CodeMeaning
Block 05Outdoor sensor not connected
Block 60Wrong minimum/maximum power parameter
Block 67Supply/return sensor difference with burner off
Block 85No water flow detected
COdEAccess code entry
CopyFactory settings restored
E00Poor flame formation (flame sensed with burner off)
E02No flame formation (ignition failure)
E04Voltage interruption / error read-out interrupted
E05Adjustment error (listed in short reference)
E12High limit stat open
E14Supply sensor T1 fault

All Rinnai Boiler error codes →

Rinnai code dES: homeowner questions

What does Rinnai code dES mean?

Descaling (automated flush) mode. Shown on the controller when the descaling mode is selected with the SW3 button on the PC board and the up or down arrow.

Is it safe to keep using my boiler with code dES?

Usually yes. Code dES is normally minor, but if it keeps coming back have it checked.

Can I reset Rinnai code dES myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code dES comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code dES near me?

Aurora Star Tech Inc. repairs Rinnai boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Rinnai I-Series Plus Condensing Combi Boiler Manual, p. 126. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.