Rinnai Error Codes & Diagnostic Codes

Updated · by Aurora Star Tech Inc.

Rinnai error codes and diagnostic codes: look up a code to see what it means, the likely causes and the steps to fix it.

Rinnai error codes by equipment type

Rinnai Air Handler error codes

CodeMeaning
Configuration menuConfiguration menu
Installer menuInstaller menu (password protected)
Status menuStatus menu (operating parameters)
Troubleshoot menuTroubleshoot menu (read operating parameters)

Rinnai Boiler error codes

CodeMeaning
00-AParameter menu entry
021Too Long DHW Continuous Operation
60Descaling countdown (minutes remaining)
100Air intake/exhaust blockage or full condensate trap
110Ignition failure
120Flame failure (flame lost during operation)
140Overheat switch tripped (heat exchanger overheating)
150Venturi control fault
161High outgoing temperature
170Venturi blockage / position mismatch
180Gas valve air/fuel adjustment limit reached
190Electrical grounding / short in DC circuit
210Data transfer error
220Gas valve position not detected (reed switch)
250Condensate pump switch tripped (accessory)
303Secondary system thermistor fault
310Freeze protection thermistor fault
321Outgoing Thermistor (Combi Only)
331Heat Exchanger Thermistor (Combi Only)
341Inlet Thermistor (Combi Only)
353CH supply thermistor fault
363CH return thermistor fault
371Indirect tank thermistor fault
380Exhaust thermistor fault
393Outdoor temperature sensor fault
400Water pressure sensor communication fault
430High or low system water pressure
443Low water cut-off (LWCO) activated
520Gas solenoid valve circuit – flame after valve close
540High exhaust (flue gas) temperature
610Combustion fan motor speed fault
631DHW Recirculation Pump (Combi Only)
651Water Flow Control (Combi Only)
661By-Pass (Combi Only)
6703-Way Valves (Combi Only)
681Hot Water Supply Temperature Abnormality (Combi Only)
700PC Board fault
710Gas solenoid circuit – valve position mismatch
720Flame rod fault
7630-10V external control input over-voltage
831Indirect tank call running too long
890Freeze condition detected
999PC Board / software mismatch
A XXDe-aeration running
Block 01External safety contact open
Block 05Outdoor sensor not connected
Block 60Wrong minimum/maximum power parameter
Block 67Supply/return sensor difference with burner off
Block 85No water flow detected
COdEAccess code entry
CopyFactory settings restored
dESDescaling (automated flush) mode
E00Poor flame formation (flame sensed with burner off)
E02No flame formation (ignition failure)
E04Voltage interruption / error read-out interrupted
E05Adjustment error (listed in short reference)
E12High limit stat open
E14Supply sensor T1 fault
E18Maximum supply temperature exceeded
E19Maximum return temperature exceeded
E28Fan speed not reported back
E31Supply sensor T1 shorted
E32Return sensor T2 shorted
E36Supply sensor T1 open
E37Return sensor T2 open
E69No or incorrect display
E393Outdoor sensor harness disconnected
E430Low water pressure in the heating system
ECLReset complete (gas solenoid circuit)
EndDescaling complete
ERROError chapter
FFFMaintenance performed marker
FHForced High Fire Mode
FILLWater pressure low / system empty
FLForced Low Fire Mode
FUSE24 V fuse defective
GoodGood state (normal)
Green button resetRestore factory parameters
HIGHWater pressure too high
Ignition safety testTest ionization lockout
INFOInformation chapter
LCLime scale detected on DHW side
PVenturi reset: first screen
PARAParameter chapter
Parameter modeParameter settings menu
PCLVenturi reset accepted
Perf dataPerformance data menu
P XXWater pressure read-out
rnSRinsing stage (descaling flush)
SESecondary unit error (cascade)
SERVService chapter
SERVICEService due
SSService Soon reminder
Status 0No heat demand
Status 1Fan pre/post purge
Status 2Ignition phase
Status 3Burner on, central heating
Status 4Burner on, domestic hot water
Status 5Fan check
Status 6Burner off, demand pending
Status 7Pump overrun, central heating
Status 8Pump overrun, hot water
Status 9Burner off, supply temperature too high
Status AAutomatic de-aeration program
StBYStandby / exit to read-out
STOPFill target reached
SW1-SW3PC board buttons (SW1, SW2, SW3)
Technical read-outTechnical read-out

Rinnai Combi Boiler error codes

CodeMeaning
021DHW continuous operation time exceeded
100Air intake/exhaust blockage or full condensate trap
110Ignition failure
120Flame failure (flame lost during operation)
140Overheat switch tripped (heat exchanger overheating)
150Venturi control fault
161High DHW outgoing water temperature
170Venturi blockage / position mismatch
180Gas valve air/fuel adjustment limit reached
190Electrical grounding / short in DC circuit
210Data transfer error
220Gas valve position not detected (reed switch)
250Condensate pump switch tripped (accessory)
303Secondary system thermistor fault
310Freeze protection thermistor fault
321Outgoing (DHW) water temperature thermistor fault
331Plate heat exchanger thermistor fault (DHW)
341DHW inlet thermistor fault
353CH supply thermistor fault
363CH return thermistor fault
380Exhaust thermistor fault
393Outdoor temperature sensor fault
400Water pressure sensor communication fault
430High or low system water pressure
443Low water cut-off (LWCO) activated
520Gas solenoid valve circuit – flame after valve close
540High exhaust (flue gas) temperature
610Combustion fan motor speed fault
631DHW recirculation pump – insufficient flow
651Water flow control valve fault
661Bypass valve fault
670Three-way valve fault
681DHW supply temperature abnormality
700PC Board fault
710Gas solenoid circuit – valve position mismatch
720Flame rod fault
7630-10V external control input over-voltage
890Freeze condition detected
999PC Board / software mismatch
ECLReset complete (gas solenoid circuit)
FFFMaintenance performed marker
LCLime condition – flush plate heat exchanger
LOCChild lock is on
PVenturi reset: first screen
Parameter modeParameter settings menu
PCLVenturi reset accepted
Perf dataPerformance data menu
SSService Soon reminder
SW1-SW3PC board buttons (SW1, SW2, SW3)

Rinnai Tankless Water Heater error codes

CodeMeaning
(blank)Status monitor: standby
--Status monitor: power just connected
1Hot water running, no controller: 120°F setting
02Burner did not operate during freeze protection
2Hot water running, no controller: 125°F setting
03Power interrupted during bath fill
3Hot water running, no controller: 135°F setting
4Hot water running, no controller: 140°F setting
05Bypass flow control device fault
07Circulation flow rate below 2.1 GPM
10Air supply or exhaust blocked / condensate trap full
11No ignition
11 (VA, VB, VC, KA, RH-180, KCM alternate checks)Code 11 - alternate checks for VA, VB, VC, KA, RH-180 and KCM
12Flame failure
13Combustion fault
14Thermal fuse or overheat sensor tripped
15Venturi control fault
16Outlet water over-temperature safety shutdown
17Venturi blockage
18Gas valve air/fuel adjustment limit reached
19Electrical grounding / DC circuit short
21PC board data transfer error
22Gas valve adjustment fault
25Condensate pump failure or clogged drain
30Flammable vapor sensor activated or faulty
31Burner thermocouple out of range
32Outlet water temperature thermistor fault
33Heat exchanger thermistor fault
34Combustion air thermistor (Non-SENSEI) / Lime detecting thermistor (RX/CX)
35Tank temperature sensor fault
38Exhaust gas temperature sensor (CO sensor on RH180)
41Freeze protection / outdoor air temperature sensor fault
51Inlet water temperature thermistor fault
52Gas valve / modulating solenoid valve (POV) signal fault
54High exhaust gas temperature
57Burner overheat bi-metal switch open
58Secondary heat exchanger bi-metal switch open
60Descaling countdown (minutes left)
61Combustion fan motor fault
63Recirculation low flow
65Water flow control device (servo) fault
66Bypass flow servo fault
70PC board fault
71Gas solenoid valve fault (SV0–SV4 on Non-SENSEI)
72Flame rod fault
73Burner thermocouple fault
79Water leakage detected
888Initial settings saved
AVenturi reset sequence: step A (RX/CX)
AdJVenturi reset sequence: step AdJ (RX/CX)
Bluetooth LED blinkingBluetooth LED blinking (push-button pairing mode)
Bluetooth LED solidBluetooth LED solid blue (app pairing mode)
dESDescaling (flush) mode
Diag historyMaintenance code history viewer (last 9 codes)
Diagnostic historyShow last 9 maintenance codes
EVenturi reset sequence: step E (code 17 or 52 only)
ECLReset complete
EndDescaling procedure ended
FVenturi reset sequence: step F
FEFlammable vapors detected
FFMaintenance performed (history marker)
FHForced high-fire combustion
FLForced low-fire combustion
InInitial setting: indoor installation
In Use fast flashIn Use light rapid flash
In Use slow flashIn Use light slow flash
In Use solidIn Use light steady
LCScale build-up in heat exchanger (LC, LC0–LC9, 00)
LC, LC0-LC9Code LC, LC0-LC9
LOCController locked (KCM)
Lock keyController locked (key symbol)
LPGInitial setting: propane (LPG)
Maint monitorKCM maintenance monitor (flow and outlet temperature)
MuteController key beeps on/off
nGInitial setting: natural gas
ONHot water running (controller installed)
OutInitial setting: outdoor installation
Parameter modeParameter settings menu
Parameter settingsParameter (installer settings) mode
Perf dataPerformance data viewer (live readings and counters)
Performance dataPerformance data readout mode
Priority lightPriority light on (this controller is in charge)
rnSDescaling finished, rinse now
SVenturi reset sequence: step S (SENSEI)
SECascade diagnostic display (error on secondary unit)
SEtInitial settings not yet confirmed
SSService Soon alert (also listed as 55)
SS (55)Code SS (55)
tVenturi reset sequence: step t
Water flow fault (no code displayed)No-code water flow fault
°C/°FTemperature scale switch (Celsius / Fahrenheit)

Rinnai Wall Furnace error codes

CodeMeaning
00Control mode setting 00 (factory default)
01Control mode setting 01 (remote thermostat mode)
02Control mode setting 02 (control panel mode)
11No ignition
14Overheat (fusible link)
16Room overheat (above 104°F / 40°C)
30Overheat temperature thermistor 2 open circuit
31Room temperature thermistor open circuit
32Room temperature thermistor short circuit
33Overheat thermistor 1 open circuit
34Overheat thermistor 1 short circuit
35Overheat temperature thermistor 2 short circuit
40Pressure sensor sensing tube failure
49Pressure sensor breakdown
53Abnormal spark sensed
61Combustion fan fault
62Convection fan fault
70ON/OFF or Set Back switch fault
71Solenoid valve failure
72Flame rod failure
73Communication error
99Flue blocked
A1-A8 / L1-L8Gas code selection (gas type, altitude, vent length)
EconomyEconomy indicator lit
FILTERFilter lamp flashing red (air filter blocked)
HSet temperature H (maximum burner output)
LSet temperature L (minimum burner output)
LockControl panel lock indicator
ON lamp greenON indicator green (powered, burner not lit)
ON lamp redON indicator red (burner lit)
PHHigh-fire gas pressure setting mode
PLLow-fire gas pressure setting mode
Set / Room tempDisplay: set temperature and room temperature
Set backSet back indicator lit (frost protection on)
Timer lampTimer lamp solid or flashing
°F/°CTemperature scale selection

Find codes by Rinnai model

Non-SENSEI

C199eC199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRU80eRU80iRU90eRU98eRU98iRUC80iRUC90iRUC98iRUCS65iRUCS75iRUR98eRUR98iRUS65eRUS75eV53DeV53eV65eV65iV75eV75iV94eV94iV94XiVE140eVE140iVE160eVE160iVE180eVE180iVE199eVE199i

SENSEI

CU160eCU160iCU199eCU199iRSC160eRSC160iRSC199eRSC199iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRUR160eRUR160iRUR199eRUR199i

SENSEI RX/CX

CX160iCX199iCXP160iCXP199iRX130iRX160iRX180iRX199iRXP160iRXP199i

EX DT

EX08DTEX11DTEX17DTEX22DTEX22DT-W

I-Series Plus 150K and smaller

IP060SIP060160CIP090SIP090099CIP090160CIP090199CIP120SIP150SIP120199CIP150199C

I-Series Plus 175K and higher

IP175SIP199SIP175199CIP199199C

RH180 hybrid

RH180

Rinnai troubleshooting guides

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.