Rinnai Error Code End: Descaling complete (Boiler)

Updated · by Aurora Star Tech Inc.

Rinnai error code End on a boiler means: Descaling complete. It is also called Rinnai diagnostic code End.

Low severityBoilerI-Series Plus

Homeowner? What Rinnai code End means for you

Usually minor Your boiler is reporting: Descaling complete. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code End mean?

Shows after the rinse steps are finished. Press Select to go back to dES, then press SW3 on the PC board to return to normal mode.

Applies to: All I-Series Plus condensing combi boilers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Rinnai Boiler codes

CodeMeaning
E36Supply sensor T1 open
E37Return sensor T2 open
E69No or incorrect display
E393Outdoor sensor harness disconnected
E430Low water pressure in the heating system
ECLReset complete (gas solenoid circuit)
ERROError chapter
FFFMaintenance performed marker
FHForced High Fire Mode
FILLWater pressure low / system empty
FLForced Low Fire Mode
FUSE24 V fuse defective

All Rinnai Boiler error codes →

Rinnai code End: homeowner questions

What does Rinnai code End mean?

Descaling complete. Shows after the rinse steps are finished. Press Select to go back to dES, then press SW3 on the PC board to return to normal mode.

Is it safe to keep using my boiler with code End?

Usually yes. Code End is normally minor, but if it keeps coming back have it checked.

Can I reset Rinnai code End myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code End comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code End near me?

Aurora Star Tech Inc. repairs Rinnai boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Rinnai I-Series Plus Condensing Combi Boiler Manual, p. 127. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.