Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rinnai Boiler: Install the outdoor temperature sensor for outdoor reset

Updated · by Aurora Star Tech Inc.

Install the outdoor temperature sensor for outdoor reset on a Rinnai boiler: Mounts the outdoor sensor so the boiler can adjust supply temperature to outdoor conditions. Keep the sensor away from direct sun and artificial heat.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: I-Series Plus Condensing Combi Boiler with outdoor reset

How to fix install the outdoor temperature sensor for outdoor reset: step by step

  1. Mount the sensor on a north-facing wall under an eave, out of direct sunlight.
  2. Keep the sensor away from vents, ducts or other heat sources.
  3. Run minimum 18 AWG wire back to the outdoor sensor terminal on the boiler.
  4. Remove the front panel (two screws) and connect the sensor to the terminals in the PC board enclosure.
  5. Make sure Parameter 00 is set to A (default).
  6. Set Parameters 01 to 03 for the application.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 93-94. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.