Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rinnai Error Code E19: Maximum return temperature exceeded (Boiler)

Updated · by Aurora Star Tech Inc.

Rinnai error code E19 on a boiler means: Maximum return temperature exceeded. It is also called Rinnai diagnostic code E19.

High severityBoilerE-Combi (E50CRN · E75CRN/E75CRP · E110CRN/E110CRP)

Homeowner? What Rinnai code E19 means for you

Call a technician Your boiler is reporting: Maximum return temperature exceeded. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code E19 mean?

The return water temperature went above 212 F.

Applies to: E50CRN; E75CRN; E75CRP; E110CRN; E110CRP

Common causes of Rinnai code E19

  • External heat source feeding the return
  • Faulty return sensor NTC2
  • Controller fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Rinnai Boiler codes

CodeMeaning
E02No flame formation (ignition failure)
E04Voltage interruption / error read-out interrupted
E05Adjustment error (listed in short reference)
E12High limit stat open
E14Supply sensor T1 fault
E18Maximum supply temperature exceeded
E28Fan speed not reported back
E31Supply sensor T1 shorted
E32Return sensor T2 shorted
E36Supply sensor T1 open
E37Return sensor T2 open
E69No or incorrect display

All Rinnai Boiler error codes →

Rinnai code E19: homeowner questions

What does Rinnai code E19 mean?

Maximum return temperature exceeded. The return water temperature went above 212 F.

Is it safe to keep using my boiler with code E19?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Rinnai code E19 myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code E19 comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code E19 near me?

Aurora Star Tech Inc. repairs Rinnai boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Rinnai E-Combi Series Installation & Servicing Instructions (8U516009 V0116), p.71-76 (15.1, 15.3). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977