Rinnai Boiler: Fluctuating DHW Outgoing Temperature (Combi Only)
Fluctuating DHW Outgoing Temperature (Combi Only) on a Rinnai boiler: DHW outlet temperature varies with no code.
Applies to: I-Series Plus combi boiler
Common causes of fluctuating dhw outgoing temperature (combi only)
- Gas pressure improper
- Water pressure improper
- DHW thermistor, flow servo or bypass servo in poor condition
- Dirty DHW inlet filter
- Air in the system
- Recirculation system in use (slight variation is normal)
How to fix fluctuating dhw outgoing temperature (combi only): step by step
- Confirm gas pressure is proper.
- Confirm water pressure is proper.
- Check the DHW thermistor, flow servo and bypass servo are in good condition.
- Clean the DHW inlet filter.
- Purge all air from the system.
If the unit shows an error code, look it up: Rinnai Boiler codes
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 117. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.