Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code CP: Remote switch off, unit blocked (Air Handler)

Updated · by Aurora Star Tech Inc.

Carrier error code CP on a air handler means: Remote switch off, unit blocked. It is also called Carrier diagnostic code CP.

Low severityAir HandlerD5FUHA

Homeowner? What Carrier code CP means for you

Usually minor Your air handler is reporting: Remote switch off, unit blocked. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code CP mean?

When the remote ON-OFF switch is open, the unit ignores commands from the remote or wired controller and CP is shown on the board.

Applies to: D5FUHA indoor unit with jumper JR1 removed

Common causes of Carrier code CP

  • Remote ON-OFF switch is in the OFF (open) position
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code CP

D5FUHAH24AAKD5FUHAH36AAKD5FUHAH60AAKEHKMD05KNEHKMD08KNEHKMD10KNEHKMD15KNEHKMD20KNEHKMD25KN

Other Carrier Air Handler codes

CodeMeaning
----IDU mode conflict
DFDefrost mode indication
EC0dODU malfunction
EC07ODU fan speed out of control
EC51ODU EEPROM parameter error
EC52ODU coil temp sensor error
EC53ODU ambient temp sensor error
EC54COMP. discharge temp sensor error
EC56IDU coil outlet temp sensor error
ECC1Other indoor unit refrigerant sensor detects leakage (multi-zone)
EH0AIDU EEPROM parameter error
EH0bIDU main control and display board communication error

All Carrier Air Handler error codes →

Carrier code CP: homeowner questions

What does Carrier code CP mean?

Remote switch off, unit blocked. When the remote ON-OFF switch is open, the unit ignores commands from the remote or wired controller and CP is shown on the board.

Is it safe to keep using my air handler with code CP?

Usually yes. Code CP is normally minor, but if it keeps coming back have it checked.

Can I reset Carrier code CP myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code CP comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code CP near me?

Aurora Star Tech Inc. repairs Carrier air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: D5FUHA service manual, p. 9. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Air Handler Emergency

647-657-2977