Carrier Air Handler: Run and cut refrigerant pipe

Updated · by Aurora Star Tech Inc.

Run and cut refrigerant pipe on a Carrier air handler: Cut and prepare the line set carefully to keep the system efficient and reduce future service calls.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FSAA / D5FLAA air handler, all sizes

How to fix run and cut refrigerant pipe: step by step

  1. Run the interconnecting piping from the outdoor unit to the indoor unit.
  2. Measure the distance between indoor and outdoor units.
  3. Cut the pipe slightly longer than that distance with a pipe cutter.
  4. Make sure the cut is a clean 90 degree angle.
  5. Ream and deburr the cut end, holding the pipe pointing down so burrs fall out. Burrs can break the air-tight seal.
  6. Complete the pipe insulation at the flare connection, then fasten the piping and wiring to the wall and seal the wall hole fully.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Handler codes

Source: Carrier D5FSAA/D5FLAA installation manual, p. 24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.