Carrier Air Handler: SLEEP mode (remote, COOL/HEAT/AUTO)
SLEEP mode (remote, COOL/HEAT/AUTO) on a Carrier air handler: SLEEP saves energy and works only in COOL, HEAT or AUTO. In COOL the setpoint rises 2°F (1°C) after 1 hour and another 2°F after a second hour, with low fan speed. In HEAT the setpoint drops by the same steps. The manual gives conflicting shutdown times (see notes). SLEEP cancels when MODE, TEMP, FAN, TIMER or ON/OFF is pressed on the remote.
Applies to: D5FS(L)AAH
How to fix sleep mode (remote, cool/heat/auto): step by step
- Press SLEEP on the remote while in COOL, HEAT or AUTO.
If the unit shows an error code, look it up: Carrier Air Handler codes
More settings shortcuts tips for air handler
Source: D5FS(L)AAH Owner's Manual, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.