Carrier Air Handler: Adding refrigerant on long pipe runs
Adding refrigerant on long pipe runs on a Carrier air handler: Standard pipe length in North America is 25 ft (7.5 m). Charge any extra refrigerant from the service port on the outdoor unit low pressure valve. Refer to the outdoor unit manual for the amount.
Applies to: D5FUAA with extra pipe length
If the unit shows an error code, look it up: Carrier Air Handler codes
Models
45MUAAQ18XX345MUAAQ24XX345MUAAQ30XX345MUAAQ36XX345MUAAQ48XX345MUAAQ60XX3D5FUAA
More other tips for air handler
Source: D5FUAA installation instructions, p. 42. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.