Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Air Handler Error Codes

Updated · by Aurora Star Tech Inc.

40 Carrier Air Handler error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Carrier Air Handler error codes list

CodeMeaningSeverity
----IDU mode conflictMedium
CPRemote switch off, unit blockedLow
DFDefrost mode indicationLow
EC0dODU malfunctionHigh
EC07ODU fan speed out of controlHigh
EC51ODU EEPROM parameter errorHigh
EC52ODU coil temp sensor errorMedium
EC53ODU ambient temp sensor errorMedium
EC54COMP. discharge temp sensor errorMedium
EC56IDU coil outlet temp sensor errorMedium
ECC1Other indoor unit refrigerant sensor detects leakage (multi-zone)Critical
EH0AIDU EEPROM parameter errorHigh
EH0bIDU main control and display board communication errorMedium
EH 0EWater level switch overflowHigh
EH0EWater-level alarm malfunctionHigh
EH00IDU EEPROM malfunctionHigh
EH03IDU fan speed out of controlHigh
EH3AExternal fan DC bus voltage too low protectionHigh
EH3bExternal fan DC bus voltage too high faultHigh
EH60IDU room temp sensor (T1) errorMedium
EH61IDU coil temp sensor (T2) errorMedium
EH62/EH66Evaporator coil inlet temp sensor (T2B) open or shortMedium
EH65Evaporator coil inlet temp sensor (T2A) open or shortMedium
EHb3Communication malfunction between wired controller and IDUMedium
EHbACommunication error between IDU and external fan moduleMedium
EHC1Refrigerant sensor detects leakageCritical
EHC2Sensor out of range and leakage detectedCritical
EHC3Refrigerant sensor working condition out of rangeHigh
EL0CSystem lacks refrigerantHigh
EL01IDU and ODU communication errorHigh
EL16Communication malfunction between adapter board and outdoor main boardMedium
FCForced cooling modeLow
FHCCRefrigerant sensor malfunctionHigh
FL09Mismatch between new and old platformsMedium
PC0LLow ambient temperature protectionMedium
PC00ODU IPM module protectionCritical
PC01ODU voltage protectionHigh
PC02Compressor top (or IPM) temperature protectionHigh
PC03Pressure protection (low or high pressure)High
PC04Inverter compressor drive errorCritical

Find codes by Carrier model

D5FUAA

45MUAAQ18XX345MUAAQ24XX345MUAAQ30XX345MUAAQ36XX345MUAAQ48XX345MUAAQ60XX3D5FUAA

D5FUHA

D5FUHAH24AAKD5FUHAH36AAKD5FUHAH60AAKEHKMD05KNEHKMD08KNEHKMD10KNEHKMD15KNEHKMD20KNEHKMD25KN

Air Handler troubleshooting guides

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Air Handler Emergency

647-657-2977