Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Air Handler: Convert to downflow or horizontal right installation

Updated · by Aurora Star Tech Inc.

Convert to downflow or horizontal right installation on a Carrier air handler: Field conversion of the air handler from upflow to downflow or horizontal right orientation. Disconnect power before starting.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FUAA downflow and horizontal right installations

How to fix convert to downflow or horizontal right installation: step by step

  1. Turn off and lock out power before working on the unit.
  2. Remove the filter door and filter.
  3. Remove the upper cover assembly.
  4. Open the electronic control box cover and remove the evaporator cover plate, then the bottom cover and second cover plate.
  5. Unplug T1, T2, T2A, T2B, the refrigerant detection sensor and the EEV from the control board.
  6. Remove the sensor, EEV and refrigerant detection sensor wire ties.
  7. Remove the evaporator and drain pan and rotate them 180° for vertical down configuration.
  8. Adjust the mounting parts to match the new airflow direction.
  9. Reinstall the evaporator and drain pan.
  10. Reconnect the T1, T2, T2A, T2B sensor plugs and EEV, then tie up the sensor wires.
  11. Cut the foam gasket and remove knockouts; route the wire through the buckle and wire slot, then replace the foam gasket over the wires.
  12. Attach the room temperature sensor with cable ties.
  13. Reconnect the wiring per the wiring diagram.
  14. Reassemble the upper cover and filter cover plate.
  15. Connect the refrigerant pipes and drain pipes.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Handler codes

Models

45MUAAQ18XX345MUAAQ24XX345MUAAQ30XX345MUAAQ36XX345MUAAQ48XX345MUAAQ60XX3D5FUAA

Source: D5FUAA installation instructions, p. 34-37. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.