Carrier Air Handler: Sleep function behaviour
Sleep function behaviour on a Carrier air handler: Sleep is available in cooling, heating, auto or heat pump plus electric heater modes. In cooling the set point rises 1.8°F (1°C) each hour up to 86°F (30°C), then holds after 2 hours with the indoor fan at low. In heating the set point drops 1.8°F (1°C) each hour down to 60.8°F (16°C), then holds after 2 hours with the fan at low. Anti-cold wind takes priority in heating.
Applies to: D5FSAA
How to fix sleep function behaviour: step by step
- Select sleep with the remote and confirm the mode is cooling, heating, auto or heat pump plus electric heater.
- Expect the set point to step by 1.8°F (1°C) per hour for 2 hours, then hold.
- In auto mode, after 1 hour the set point moves 1.8°F (1°C) up for cooling or down for heating; in fan mode it does not change.
If the unit shows an error code, look it up: Carrier Air Handler codes
More other tips for air handler
Source: Carrier D5FSAA product data, p. 4. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.