Carrier Air Handler: Humidifier connection through the WORK output (CN23)
Humidifier connection through the WORK output (CN23) on a Carrier air handler: The WORK output is tied to the fan. Its relay closes whenever the fan runs, which lets power reach the humidifier when the humidistat calls for humidity. The humidistat and humidifier are wired as shown in the diagram with the R and C wires.
Applies to: D5FUHA with humidifier
How to fix humidifier connection through the work output (cn23): step by step
- Wire the humidistat and humidifier per the wiring diagram, using CN23 and the R and C terminals.
- If the thermostat has a HUM terminal, connect the humidifier directly to HUM and C instead.
If the unit shows an error code, look it up: Carrier Air Handler codes
Models
D5FUHAH24AAKD5FUHAH36AAKD5FUHAH60AAKEHKMD05KNEHKMD08KNEHKMD10KNEHKMD15KNEHKMD20KNEHKMD25KN
More other tips for air handler
Source: Carrier D5FUHA installation instructions, p. 42. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.