Carrier Air Handler: Enter INQUIRY mode on the remote
Enter INQUIRY mode on the remote on a Carrier air handler: Opens the remote's INQUIRY menu, which holds numbered codes 0 to 30 used for checking and setting the unit. Other buttons do nothing in this mode except UP, DOWN and OK, or the exit combination.
Applies to: D5FUHA remote controller
How to fix enter inquiry mode on the remote: step by step
- Press ON/OFF and FAN SPEED together and hold for 8 seconds.
- The remote display shows 0 on entry. Use UP or DOWN to move through codes 0 to 30.
- Each code's information shows on the indoor unit display in about 1 second. Press OK to send the value.
- If no button is pressed, the remote leaves INQUIRY mode after 1 minute.
- To leave INQUIRY mode, press ON/OFF and FAN SPEED together for 2 seconds.
If the unit shows an error code, look it up: Carrier Air Handler codes
Models
D5FUHAH24AAKD5FUHAH36AAKD5FUHAH60AAKEHKMD05KNEHKMD08KNEHKMD10KNEHKMD15KNEHKMD20KNEHKMD25KN
More service & test modes tips for air handler
Source: D5FUHA installation instruction manual, p. 49. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.