Carrier Air Handler: Record INQUIRY changes because the remote does not show them
Record INQUIRY changes because the remote does not show them on a Carrier air handler: A changed value does not show again when INQUIRY is reopened. The display falls back to the default of 0, so the old setting can only be known from your own records.
Applies to: Wireless remote controller, D5FSAA and D5FLAA air handler ductless systems
How to fix record inquiry changes because the remote does not show them: step by step
- Write down every INQUIRY and SERVICE change, with the code number and new value.
- If the previous value is unknown, press DOWN to the maximum change range (-6 in the code 22 example).
- Press UP until the display is back at 0.
- Enter the new value and document it.
If the unit shows an error code, look it up: Carrier Air Handler codes
More access & passwords tips for air handler
Source: Carrier D5FSAA/D5FLAA installation instructions, p. 35. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.