Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Codes & Diagnostic Codes

Updated · by Aurora Star Tech Inc.

Carrier error codes and diagnostic codes: look up a code to see what it means, the likely causes and the steps to fix it.

Carrier error codes by equipment type

Carrier Air Conditioner error codes

CodeMeaning
1Normal operation - 1 flash
1 longCapacity limited - one long flash
2Normal operation - 2 flashes (high stage)
4Four flashes - speed limiting, non-communicating thermostat
5Five flashes - brownout protection setting (24ANB/25HNB)
6Six flashes - brownout protection setting (24ANB/25HNB)
16Lost communication with user interface
25Invalid model plug / inverter size
31High pressure switch open
32Low pressure trip
33Lost inverter communication
45Outdoor control board failure
46Brownout
47No 230 V at unit
48Lost inverter communication - lockout
49Compressor over current
53Outdoor air temperature sensor fault
54Suction temperature sensor fault
55Outdoor coil temperature sensor fault
56OAT / coil thermistor out of range
57Suction pressure transducer fault
59Discharge temperature high (event)
61Fan inverter fault
63Fan inverter current fault
65DC bus voltage low - speed limiting
66Outdoor fan dropped out
67Stator heater fault
6810-minute stage 2 warm-up delay
69Inverter / compressor internal fault
71Compressor dropped out
72Suction over temperature (event)
73Contactor shorted
74Discharge temperature lockout
75Maximum power mode - temperature
76Fan inverter lockout
77Maximum power mode - compressor current
79Compressor / inverter fault (failed start)
81Low stage thermal lockout
82Suction over temperature lockout
83Low pressure lockout (4 hours)
84High pressure lockout (4 hours)
86Fan inverter current lockout
88Compressor / inverter lockout
91Inverter DC over voltage (event)
92Inverter DC under voltage (event)
95Compressor over current lockout
96DC under voltage lockout
97DC over voltage lockout
98High torque event
99High torque lockout
Charging modeRefrigerant charging mode (25VNA8/24VNA9, communicating)
COMM LEDGreen COMM LED on - communicating
CurtailmentUtility curtailment shown on user interface
LD1MOC red LED LD1 (sizes 25-60)
LD5MOC green LED LD5 (sizes 25-60)
LED1MOC red LED1 (sizes 25-60)
LED3MOC amber LED3 (sizes 25-60)
LED200MOC red LED (sizes 13, 24B)
LED207MOC amber LED (sizes 13, 24B)
ONAmber STATUS LED on solid - standby
Status code recallStatus code recall mode (25VNA8/24VNA9)

Carrier Air Handler error codes

CodeMeaning
----IDU mode conflict
CPRemote switch off, unit blocked
DFDefrost mode indication
EC0dODU malfunction
EC07ODU fan speed out of control
EC51ODU EEPROM parameter error
EC52ODU coil temp sensor error
EC53ODU ambient temp sensor error
EC54COMP. discharge temp sensor error
EC56IDU coil outlet temp sensor error
ECC1Other indoor unit refrigerant sensor detects leakage (multi-zone)
EH0AIDU EEPROM parameter error
EH0bIDU main control and display board communication error
EH 0EWater level switch overflow
EH0EWater-level alarm malfunction
EH00IDU EEPROM malfunction
EH03IDU fan speed out of control
EH3AExternal fan DC bus voltage too low protection
EH3bExternal fan DC bus voltage too high fault
EH60IDU room temp sensor (T1) error
EH61IDU coil temp sensor (T2) error
EH62/EH66Evaporator coil inlet temp sensor (T2B) open or short
EH65Evaporator coil inlet temp sensor (T2A) open or short
EHb3Communication malfunction between wired controller and IDU
EHbACommunication error between IDU and external fan module
EHC1Refrigerant sensor detects leakage
EHC2Sensor out of range and leakage detected
EHC3Refrigerant sensor working condition out of range
EL0CSystem lacks refrigerant
EL01IDU and ODU communication error
EL16Communication malfunction between adapter board and outdoor main board
FCForced cooling mode
FHCCRefrigerant sensor malfunction
FL09Mismatch between new and old platforms
PC0LLow ambient temperature protection
PC00ODU IPM module protection
PC01ODU voltage protection
PC02Compressor top (or IPM) temperature protection
PC03Pressure protection (low or high pressure)
PC04Inverter compressor drive error

Carrier Furnace error codes

CodeMeaning
##.#Active status code shown as major.minor number
5,9Component test - gas valve communication check (59MN7C)
10.1L1 polarity fault
11No previous code
12Blower on after power-up (normal)
12.1W (heat call) on at power up
13Limit circuit lockout
13.1Limit lockout - main limit open over 3 minutes
14Ignition lockout
14.1Ignition lockout after 4 tries
14.2Lockout - flame lost 3 times after 70 s of heating
14.3Lockout - 7 flame-loss events in one heat call
15Blower motor lockout
21Gas heating lockout
21.124 VAC on gas valve when it should be off
22Abnormal flame-proving signal
22.1False flame
23Pressure switch did not open
23.1Main pressure switch stuck closed
23.2Secondary pressure switch stuck closed
24Secondary (24 V) fuse open
24.1Fuse fault (24 V)
25Invalid model selection or setup error
25.1No program in control
25.2Corrupted program file
25.3Twinned furnaces not identical
25.4Main program invalid, running on backup
25.5Installer settings corrupted
25.6Wrong program for this control
25.7Non-condensing program in condensing furnace
27.1Super plug program missing or corrupted
27.2Super plug program missing or corrupted
27.3Super plug program missing or corrupted
31High-heat pressure switch or relay did not close or reopened
31.2Secondary pressure switch (HPS) open
31.3Secondary pressure switch lockout
32Low-heat pressure switch did not close or reopened
32.1Main pressure switch (LPS) open
33Limit circuit fault
33.1Main limit circuit switch open
34Ignition proving failure
34.1Ignition fault during ignition trials
34.2Flame lost before blower on-delay
34.3Flame lost after blower on-delay
43Low-heat pressure switch open while high-heat switch closed
45Control circuitry lockout
45.1Control failure - flame circuit / memory / sequence
45.2Control failure - gas valve relay will not close
45.3Control failure - EEPROM memory
46.1Momentary loss of power
AirMenu: airflow (CFM) display on/off
bLrBlower running (secondary furnace / communicating system)
bStMenu: inducer boost
CF2Continuous fan (CF2 variant)
CF3Continuous fan (CF3 variant)
CfnContinuous fan
CLCooling or heat pump running (59SC6A)
CL1Low cooling or heat pump (PG96VTA, 59MN7C)
CL2High cooling or heat pump (PG96VTA, 59MN7C)
ClrClear fault history
CodMenu: cool blower-off delay
Component testComponent self-test mode
CtMenu: component test
CttMenu: cooling thermostat type
dirMenu: display orientation
dnFDisplay set for downflow
EndComponent test - end
ErrComponent test could not start
FLtMenu: last 7 faults
FnComponent test - blower
HoDMenu: heat blower-off delay
HpdHeat pump defrost - furnace heating
HSiComponent test - hot surface igniter
HtHeating (59SC6A, 59MN7C menu: heating airflow setting)
Ht-%Heating at a percent firing rate (59MN7C)
Ht1Low-stage heating (PG96VTA)
Ht2High-stage heating (PG96VTA)
HttMenu: heating thermostat type
iDlIdle - standby, no demand
inFMenu: program number and software
LED OFFNo amber LED - no power to control
LED ONAmber LED steady on
nonNo faults stored
PRGStartup display - model program number
PriTwinning: primary furnace
PUrComponent test - purge (inducer on)
Rapid FlashReversed 115-V polarity (or twinning phasing)
rStMenu: reset to factory defaults
SECTwinning: secondary furnace
Stored codesRecall stored status codes
tnnMenu: twinning
tStComponent test started
t°Menu: supply and return air temperature display
uErStartup display - software version
UPFDisplay set for upflow
YEsReset confirmation

Carrier Heat Pump error codes

CodeMeaning
----Indoor units mode conflict
1Normal operation - 1 flash
1 longCapacity limited - one long flash
2Normal operation - 2 flashes (high stage)
3Three flashes - outdoor fan delay after defrost active (24ANB/25HNB)
4Four flashes - speed limiting (25VNA8) / fan delay defeat on (24ANB/25HNB)
5Five flashes - brownout protection setting (24ANB/25HNB)
6Six flashes - brownout protection setting (24ANB/25HNB)
16Lost communication with user interface
25Invalid model plug / inverter size
31High pressure switch open
32Low pressure trip
33Lost inverter communication
45Outdoor control board failure
46Brownout
47No 230 V at unit
48Lost inverter communication - lockout
49Compressor over current
53Outdoor air temperature sensor fault
54Suction temperature sensor fault
55Outdoor coil temperature sensor fault
56OAT / coil thermistor out of range
57Suction pressure transducer fault
59Discharge temperature high (event)
61Fan inverter fault
63Fan inverter current fault
65DC bus voltage low - speed limiting
66Outdoor fan dropped out
67Stator heater fault
6810-minute stage 2 warm-up delay
69Inverter / compressor internal fault
71Compressor dropped out
72Suction over temperature (event)
73Contactor shorted
74Discharge temperature lockout
75Maximum power mode - temperature
76Fan inverter lockout
77Maximum power mode - compressor current
79Compressor / inverter fault (failed start)
81Low stage thermal lockout
82Suction over temperature lockout
83Low pressure lockout (4 hours)
84High pressure lockout (4 hours)
86Fan inverter current lockout
88Compressor / inverter lockout
91Inverter DC over voltage (event)
92Inverter DC under voltage (event)
95Compressor over current lockout
96DC under voltage lockout
97DC over voltage lockout
98High torque event
99High torque lockout
341 MCE error341 MCE error
Charging modeRefrigerant charging mode (25VNA8/24VNA9, communicating)
COMM LEDGreen COMM LED on - communicating
CurtailmentUtility curtailment shown on user interface
DFDefrost mode
EC 0dOutdoor unit malfunction
EC0dODU malfunction
EC 07Outdoor fan speed operating outside normal range
EC07ODU fan speed out of control
EC 5CQuick maintenance code (outdoor)
EC 50Temperature sensor open or shorted
EC 51EEPROM malfunction (outdoor unit)
EC51ODU EEPROM parameter error
EC 52Outdoor temperature sensor open or short
EC52ODU coil temp sensor error
EC 53Outdoor temperature sensor open or short
EC53ODU ambient temp sensor error
EC 54Outdoor temperature sensor open or short
EC54COMP. discharge temp sensor error
EC 55Quick maintenance code (outdoor)
EC 56Outdoor temperature sensor open or short
EC56IDU coil outlet temp sensor error
EC 57Quick maintenance code (outdoor)
ECC1Other IDU refrigerant sensor detects leakage (multi-zone)
EH 0AEEPROM malfunction (indoor unit)
EH0AIDU EEPROM parameter error
EH 0bIndoor main control board and display board communication error
EH0bIDU main control and display boards communication error
EH0EWater-level alarm malfunction
EH 0EWater-level alarm malfunction
EH 00EEPROM malfunction (indoor unit)
EH00IDU EEPROM malfunction
EH 03Indoor fan speed outside normal range
EH03IDU fan speed out of control
EH 03 / EC 07Fan speed outside normal range
EH 3AExternal fan DC bus voltage too low protection
EH3AExternal fan DC bus voltage too low protection
EH 3bExternal fan DC bus voltage too high fault
EH3bExternal fan DC bus voltage too high fault
EH 60Indoor temperature sensor open or short
EH60IDU room temp. sensor (T1) error
EH 61Indoor temperature sensor open or short
EH61IDU coil temp. sensor (T2) error
EH 62Indoor temperature sensor open or short
EH62/EH66Evaporator coil inlet temp. sensor (T2B) open or short circuit
EH 65Indoor temperature sensor open or short
EH65Evaporator coil inlet temp. sensor (T2A) open or short circuit
EH 66Indoor temperature sensor open or short
EH b3Communication malfunction between wired controller and master control
EHb3Communication malfunction between wire controller and master control
EH bACommunication malfunction between indoor unit and external fan module
EHbACommunication error between indoor unit and external fan module
EH C1Refrigerant sensor detects leakage
EHC1Refrigerant sensor detects leakage
EH C2Refrigerant sensor out of range and leakage detected
EHC2Refrigerant sensor out of range and leakage detected
EH C3Refrigerant sensor out of range
EHC3Refrigerant sensor out of range
EL 0CSystem lacks refrigerant
EL0CSystem lacks refrigerant
EL 01Indoor and outdoor unit communication error
EL01IDU & ODU communication error
EL 16Communication malfunction between adapter board and outdoor main board
EL16Communication malfunction between adapter board and outdoor main board
FCForced cooling mode
FH CCRefrigerant sensor error
FHCCRefrigerant sensor error
FL 09Mismatch between new and old platforms
FL09Mismatch between the new and old platforms
Forced defrostForced defrost (short the defrost pins)
LC 06Compressor top (IPM) temperature protection
LD1MOC red LED LD1 (sizes 25-60)
LD5MOC green LED LD5 (sizes 25-60)
LED1MOC red LED1 (sizes 25-60)
LED3MOC amber LED3 (sizes 25-60)
LED200MOC red LED (sizes 13, 24B)
LED207MOC amber LED (sizes 13, 24B)
ONAmber STATUS LED on solid - standby
PC 0aQuick maintenance code (outdoor)
PC 0FQuick maintenance code (outdoor)
PC 0LLow ambient temperature protection
PC0LLow ambient temp. protection
PC00ODU IPM module protection
PC 00Outdoor IPM module protection
PC01ODU voltage protection
PC 01Outdoor voltage protection
PC02Compressor top (or IPM) temp. protection
PC 02Compressor top or IPM temperature protection
PC03Pressure protection (low or high pressure)
PC 03High or low pressure protection
PC04Inverter compressor drive error
PC 04Inverter compressor drive error
PC 06Quick maintenance code (outdoor)
PC 08Quick maintenance code (outdoor)
PC 10Quick maintenance code (outdoor)
PC 11Quick maintenance code (outdoor)
PC 12Quick maintenance code (outdoor)
PC 30Quick maintenance code (outdoor)
PC 31Quick maintenance code (outdoor)
PC 40Quick maintenance code (outdoor)
PC 41Quick maintenance code (outdoor)
PC 42Quick maintenance code (outdoor)
PC 43Quick maintenance code (outdoor)
PC 44Quick maintenance code (outdoor)
PC 45Quick maintenance code (outdoor)
PC 46Quick maintenance code (outdoor)
PC 49Quick maintenance code (outdoor)
PH 90Quick maintenance code (outdoor)
PH 91Quick maintenance code (outdoor)
Status code recallStatus code recall mode (25VNA8/24VNA9)

Carrier Mini-Split error codes

CodeMeaning
--Indoor units mode conflict
---Mode conflict fault
----IDUs mode conflict
APWi-Fi pairing (AP mode)
CLFilter cleaning reminder / Active Clean
CPRemote switched off
CSService setting uploaded successfully
d1Demand response signal DR1 received
d2Demand response signal DR2 received
d3Demand response signal DR3 received
dEDemand response input error
dFDefrost
E1Indoor / outdoor communication error
EC0dODU malfunction
EC 0dOutdoor unit malfunction detected by indoor unit
EC07Outdoor fan speed out of range
EC 07Fan speed out of control (outdoor)
EC5CFault listed in quick maintenance
EC 5CError code EC 5C
EC50Outdoor temperature sensor fault
EC51Outdoor EEPROM error
EC 51EEPROM malfunction (outdoor PCB)
EC52Condenser coil sensor (T3) fault
EC 52Temperature sensor open or short circuit
EC53Outdoor ambient sensor (T4) fault
EC 53Temperature sensor open or short circuit
EC54Discharge temperature sensor (TP/T5) fault
EC 54Temperature sensor open or short circuit
EC55IPM temperature sensor fault
EC 55Error code EC 55
EC56Indoor coil outlet sensor (T2B) fault
EC 56Temperature sensor open or short circuit
EC57Refrigerant pipe sensor fault
EC 57Error code EC 57
EC71Outdoor fan motor over-current
EC72Outdoor fan motor phase loss
ECC1Other IDU refrigerant sensor detects leakage (multi-zone)
EH0AIndoor EEPROM error
EH 0AEEPROM malfunction (indoor PCB)
EH0bIndoor PCB to display board communication error
EH 0bIndoor main board and display board communication error
EH0EWater-level alarm malfunction
EH 0EWater-level alarm malfunction
EH00Indoor EEPROM error
EH 00EEPROM malfunction (indoor PCB)
EH02Zero-crossing signal error
EH03Indoor fan speed out of range
EH 03Fan speed out of control (indoor)
EH 06Indoor PCB and display board communication error
EH06Indoor PCB / display board communication error
EH3AExternal fan DC bus voltage too low (protection)
EH 3AExternal fan DC bus voltage too low
EH3bExternal fan DC bus voltage too high (fault)
EH 3bExternal fan DC bus voltage too high
EH12Main or secondary unit malfunction
EH30Indoor external fan low voltage
EH31Indoor external fan over voltage
EH32High DC bus voltage of the external fan
Eh60Room sensor (T1) fault
EH 60Temperature sensor open or short circuit (indoor)
Eh61Indoor coil sensor (T2) fault
EH 61Temperature sensor open or short circuit (indoor)
EH62Evaporator coil inlet temperature sensor (T2B) open or short circuit
EH 62Indoor temperature sensor open or shorted
EH62/EH66Evap coil inlet temp sensor (T2B) open or short circuit
EH65Evap coil inlet temp. sensor (T2A) open or short circuit
EH 65Indoor temperature sensor open or shorted
EH66Evaporator coil inlet temperature sensor (T2B) open or short circuit
EH 66Indoor temperature sensor open or shorted
EHb3Communication error between wire and master control
EH b3Communication fault between wired controller and indoor master control
EHbACommunication error between indoor unit and external fan module
EH bACommunication error between indoor unit and external fan module
EHC1Refrigerant sensor detects leakage
EH C1Refrigerant sensor detects leakage
EHC2Refrigerant sensor out of range with leakage detected
EH C2Refrigerant sensor out of range and leakage detected
EHC3Refrigerant sensor out of range
EH C3Refrigerant sensor out of range
EL0CRefrigerant leak detected
EL 0CSystem lacks refrigerant
EL01Indoor / outdoor communication error
EL 01Indoor and outdoor unit communication error
EL11Communication fault between main and secondary units
EL16Communication malfunction between adapter board and outdoor main board
EL 16Error code EL 16
F0Current overload protection
F1Outdoor ambient sensor (T4) fault
F2Condenser coil sensor (T3) fault
F3Discharge sensor (T5) fault
F4Outdoor EEPROM error
F5Outdoor fan speed out of control
FbVapor injection inlet sensor fault
FCForced cooling
FdVapor injection outlet sensor fault
FH0CIndoor unit humidity sensor malfunction
FH 0dFault - see outdoor unit
FH 0PAP mode on / no Wi-Fi kit
FH0PWireless module self-test failure
FH07Indoor unit lift panel communication failure / opening and closing failure
FHCCRefrigerant sensor error
FH CCRefrigerant sensor error
FL09Mismatch between the new and old platforms
FL 09Mismatch between new and old platforms
FL14Indoor and outdoor units not compatible
FPLow-temperature heating (8 C mode)
J0Outdoor coil overheat in cooling
J1Indoor coil temperature protection in heating
J2Discharge temperature protection
J3PFC module protection
J4Main board to IPM board communication error
J5High pressure protection
J6Low pressure protection
J8AC voltage protection
LC01Speed limited by condenser temperature
LC02Speed limited by discharge temperature
LC03Speed limited by current
LC05Speed limited by voltage
LC06IPM high temperature / PFC frequency limit
LH00Speed limited by indoor coil temperature
LH07Speed limited by remote
LLControls locked
nANo fault
nFFilter replacement reminder
ODU --Outdoor board standby
ODU 00Wiring / piping check finished
ODU CEAutomatic wiring / piping check running
ODU E0Outdoor EEPROM error (outdoor board)
ODU E2Indoor / outdoor communication error (outdoor board)
ODU E3IPM to main board communication error (outdoor board)
ODU E4Outdoor or T2B sensor fault (outdoor board)
ODU E5Over or under voltage (outdoor board)
ODU E6PFC module protection (outdoor board)
ODU E8Outdoor fan speed fault (outdoor board)
ODU EdAdapter / inverter board to main board communication error
ODU F1Zone A coil outlet sensor (T2B-A) fault
ODU F2Zone B coil outlet sensor (T2B-B) fault
ODU F3Zone C coil outlet sensor (T2B-C) fault
ODU F4Zone D coil outlet sensor (T2B-D) fault
ODU F5Zone E coil outlet sensor (T2B-E) fault
ODU F6Zone F coil outlet sensor (T2B-F) fault
ODU Hz readoutCompressor running frequency
ODU LCLow ambient cooling mode
ODU LPLow outdoor temperature protection (outdoor board)
ODU P0Compressor top overheat (outdoor board)
ODU P1High pressure protection (outdoor board)
ODU P2Low pressure protection (outdoor board)
ODU P3Current overload (outdoor board)
ODU P4Discharge temperature protection (outdoor board)
ODU P5Condenser high temperature (outdoor board)
ODU P6Inverter module (IPM) fault (outdoor board)
ODU PHCompressor pre-heat
ODU ROOil return cycle
OffTimer off
OnTimer on
P0Inverter module (IPM) fault
P1Over or under voltage protection
P2Compressor top overheat (OLP)
P3Low outdoor temperature cut-off in heating
P4Compressor drive fault
P7IPM temperature sensor fault
PC0ACondenser high temperature protection
PC 0aError code PC 0a
PC0FPFC module protection
PC 0FError code PC 0F
PC0LOutdoor temperature too low
PC 0LLow ambient temperature protection
PC00Inverter module (IPM) protection
PC 00Error code PC 00
PC01ODU voltage protection
PC 01Outdoor voltage protection
PC02Compressor top overheat (OLP)
PC 02Error code PC 02
PC03Pressure protection
PC 03High or low pressure protection
PC03/PC30/PC31Pressure protection (low or high pressure)
PC04Inverter compressor drive error
PC 04Inverter compressor drive error
PC06Discharge temperature protection
PC 06Error code PC 06
PC08Outdoor over-current protection
PC 08Error code PC 08
PC10Low AC supply voltage
PC 10Error code PC 10
PC11AC supply voltage protection (over voltage)
PC 11Error code PC 11
PC12DC bus high voltage / 341 MCE error
PC 12Error code PC 12
PC30High pressure protection
PC 30Error code PC 30
PC31Low pressure protection
PC 31Error code PC 31
PC40Main chip to compressor drive chip communication error
PC 40Error code PC 40
PC41Current input detection protection
PC 41Error code PC 41
PC42Compressor start failure
PC 42Error code PC 42
PC43Compressor phase loss
PC 43Error code PC 43
PC44Zero speed protection
PC 44Error code PC 44
PC45Compressor drive chip (IR / 341 PWM) failure
PC 45Error code PC 45
PC46Compressor speed out of control
PC 46Error code PC 46
PC49Compressor over-current
PC 49Error code PC 49
PCA1Refrigerant pipe condensation protection
PH09Anti-cold-air in heating
PH90Evaporator coil too hot
PH 90Error code PH 90
PH91Evaporator coil too cold
PH 91Error code PH 91
SCSelf clean running
SDPower abnormal detection

Find codes by Carrier model

Carrier 2-stage 24ANB/25HNB

24ANB12424ANB13624ANB14824ANB16024ANB72424ANB73624ANB74824ANB76025HNB62425HNB63625HNB64825HNB66025HNB92425HNB93625HNB94825HNB960

Carrier Infinity 19VS 24VNA9

24VNA924VNA91324VNA92424VNA92524VNA93624VNA93724VNA94824VNA94924VNA960

Carrier Infinity 18VS 25VNA8

25VNA81325VNA82425VNA82525VNA83625VNA83725VNA84825VNA860

D5FCFA

37MAHAQ37MARAQ37MGHAQ37MGRAQD5FCFAH18XAKD5FCFAH24XAKD5FCFAH36XAKD5FCFAH48XAKD5FCFAH58XAKD5FCFH18XAKD5FCFH24XAKD5FCFH36XAKD5FCFH48XAKD5FCFH58XAKD5SCHA

D5FUAA

37MUHA37MURA45MUAAQ18XX345MUAAQ24XX345MUAAQ30XX345MUAAQ36XX345MUAAQ48XX345MUAAQ60XX3D5FUAAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK

D5FSCAH / D5FLCAH

45MBCAQ12XA3D5FLCAH36XAKD5FLCAH48XAKD5FSCAH12XAKD5FSCAH18XAKD5FSCAH24XAK

58SB0A/58SB1A

58SB0A045E14--1258SB0A045E17--1258SB0A070E14--1258SB0A070E17--1258SB0A070E17--1658SB0A070E21--1658SB0A090E17--1458SB0A090E21--1658SB0A090E21--2058SB0A090E24--2058SB0A110E21--2058SB0A110E24--2058SB0A135E24--2058SB0A155E24--20

59MN7C

59MN7C060C17--1459MN7C060C21--2059MN7C080C17--1459MN7C080C21--2059MN7C100C21--2259MN7C120C24--22

59SC6A

59SC6A026M14--1059SC6A040M14--1059SC6A040M17--1259SC6A060M14--1259SC6A060M17--1659SC6A080M17--1659SC6A080M21--2059SC6A100M21--2059SC6A100M21--2259SC6A120M24--2259SC6A140M24--22

59TP6A

59TP6A040-1059TP6A040-1259TP6A060-1259TP6A060-1459TP6A080-1659TP6A080-2059TP6A100-2059TP6A120-22

D5CURA

D5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAK

D5FSFAH

D5FSFAH

D5FSFA

D5FSFAH09XAKD5FSFAH12XAKD5FSFAH16XAK

D5FSHAH

D5FSHAH

D5FSOA

D5FSOAH06XAKD5FSOAH12XAKD5FSOAH18XAK

D5FUHA

D5FUHAH24AAKD5FUHAH36AAKD5FUHAH60AAKEHKMD05KNEHKMD08KNEHKMD10KNEHKMD15KNEHKMD20KNEHKMD25KN

Carrier DLCM(R/H)B multi-zone outdoor

DLCMHBH24CAKDLCMHBH30DAKDLCMHBH36DAKDLCMHBH48EAKDLCMRBH18BAKDLCMRBH36DAKDLCMRBH48EAK

Carrier DLFSHB high wall indoor

DLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Payne PG96VTA

PG96VTA30040APG96VTA36040BPG96VTA36060APG96VTA48060BPG96VTA48080BPG96VTA60080CPG96VTA60100CPG96VTA66120D

D5FS(L)AAH

RG10F8(2)/BGEFU1

Carrier troubleshooting guides

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977