Carrier error codes by equipment type

Carrier Air Conditioner error codes

CodeMeaning
16Lost communication with user interface
25Invalid model plug / inverter size
31High pressure switch open
32Low pressure trip
33Lost inverter communication
45Outdoor control board failure
46Brownout
47No 230 V at unit
48Lost inverter communication - lockout
49Compressor over current
53Outdoor air temperature sensor fault
54Suction temperature sensor fault
55Outdoor coil temperature sensor fault
56OAT / coil thermistor out of range
57Suction pressure transducer fault
59Discharge temperature high (event)
61Fan inverter fault
63Fan inverter current fault
65DC bus voltage low - speed limiting
66Outdoor fan dropped out
67Stator heater fault
6810-minute stage 2 warm-up delay
69Inverter / compressor internal fault
71Compressor dropped out
72Suction over temperature (event)
73Contactor shorted
74Discharge temperature lockout
75Maximum power mode - temperature
76Fan inverter lockout
77Maximum power mode - compressor current
79Compressor / inverter fault (failed start)
81Low stage thermal lockout
82Suction over temperature lockout
83Low pressure lockout (4 hours)
84High pressure lockout (4 hours)
86Fan inverter current lockout
88Compressor / inverter lockout
91Inverter DC over voltage (event)
92Inverter DC under voltage (event)
95Compressor over current lockout
96DC under voltage lockout
97DC over voltage lockout
98High torque event
99High torque lockout

Carrier Furnace error codes

CodeMeaning
10.1L1 polarity fault
11No previous code
12Blower on after power-up (normal)
12.1W (heat call) on at power up
13Limit circuit lockout
13.1Limit lockout - main limit open over 3 minutes
14Ignition lockout
14.1Ignition lockout after 4 tries
14.2Lockout - flame lost 3 times after 70 s of heating
14.3Lockout - 7 flame-loss events in one heat call
15Blower motor lockout
21Gas heating lockout
21.124 VAC on gas valve when it should be off
22Abnormal flame-proving signal
22.1False flame
23Pressure switch did not open
23.1Main pressure switch stuck closed
23.2Secondary pressure switch stuck closed
24Secondary (24 V) fuse open
24.1Fuse fault (24 V)
25Invalid model selection or setup error
25.1No program in control
25.2Corrupted program file
25.3Twinned furnaces not identical
25.4Main program invalid, running on backup
25.5Installer settings corrupted
25.6Wrong program for this control
25.7Non-condensing program in condensing furnace
27.1Super plug program missing or corrupted
27.2Super plug program missing or corrupted
27.3Super plug program missing or corrupted
31High-heat pressure switch or relay did not close or reopened
31.2Secondary pressure switch (HPS) open
31.3Secondary pressure switch lockout
32Low-heat pressure switch did not close or reopened
32.1Main pressure switch (LPS) open
33Limit circuit fault
33.1Main limit circuit switch open
34Ignition proving failure
34.1Ignition fault during ignition trials
34.2Flame lost before blower on-delay
34.3Flame lost after blower on-delay
43Low-heat pressure switch open while high-heat switch closed
45Control circuitry lockout
45.1Control failure - flame circuit / memory / sequence
45.2Control failure - gas valve relay will not close
45.3Control failure - EEPROM memory
46.1Momentary loss of power
LED OFFNo amber LED - no power to control
Rapid FlashReversed 115-V polarity (or twinning phasing)

Carrier Heat Pump error codes

CodeMeaning
16Lost communication with user interface
25Invalid model plug / inverter size
31High pressure switch open
32Low pressure trip
33Lost inverter communication
45Outdoor control board failure
46Brownout
47No 230 V at unit
48Lost inverter communication - lockout
49Compressor over current
53Outdoor air temperature sensor fault
54Suction temperature sensor fault
55Outdoor coil temperature sensor fault
56OAT / coil thermistor out of range
57Suction pressure transducer fault
59Discharge temperature high (event)
61Fan inverter fault
63Fan inverter current fault
65DC bus voltage low - speed limiting
66Outdoor fan dropped out
67Stator heater fault
6810-minute stage 2 warm-up delay
69Inverter / compressor internal fault
71Compressor dropped out
72Suction over temperature (event)
73Contactor shorted
74Discharge temperature lockout
75Maximum power mode - temperature
76Fan inverter lockout
77Maximum power mode - compressor current
79Compressor / inverter fault (failed start)
81Low stage thermal lockout
82Suction over temperature lockout
83Low pressure lockout (4 hours)
84High pressure lockout (4 hours)
86Fan inverter current lockout
88Compressor / inverter lockout
91Inverter DC over voltage (event)
92Inverter DC under voltage (event)
95Compressor over current lockout
96DC under voltage lockout
97DC over voltage lockout
98High torque event
99High torque lockout

Find codes by Carrier model

Carrier 2-stage 24ANB/25HNB

24ANB12424ANB13624ANB14824ANB16024ANB72424ANB73624ANB74824ANB76025HNB62425HNB63625HNB64825HNB66025HNB92425HNB93625HNB94825HNB960

Carrier Infinity 19VS 24VNA9

24VNA924VNA91324VNA92424VNA92524VNA93624VNA93724VNA94824VNA94924VNA960

Carrier Infinity 18VS 25VNA8

25VNA81325VNA82425VNA82525VNA83625VNA83725VNA84825VNA860

58SB0A/58SB1A

58SB0A045E14--1258SB0A045E17--1258SB0A070E14--1258SB0A070E17--1258SB0A070E17--1658SB0A070E21--1658SB0A090E17--1458SB0A090E21--1658SB0A090E21--2058SB0A090E24--2058SB0A110E21--2058SB0A110E24--2058SB0A135E24--2058SB0A155E24--20

59MN7C

59MN7C060C17--1459MN7C060C21--2059MN7C080C17--1459MN7C080C21--2059MN7C100C21--2259MN7C120C24--22

59SC6A

59SC6A026M14--1059SC6A040M14--1059SC6A040M17--1259SC6A060M14--1259SC6A060M17--1659SC6A080M17--1659SC6A080M21--2059SC6A100M21--2059SC6A100M21--2259SC6A120M24--2259SC6A140M24--22

59TP6A

59TP6A040-1059TP6A040-1259TP6A060-1259TP6A060-1459TP6A080-1659TP6A080-2059TP6A100-2059TP6A120-22

Payne PG96VTA

PG96VTA30040APG96VTA36040BPG96VTA36060APG96VTA48060BPG96VTA48080BPG96VTA60080CPG96VTA60100CPG96VTA66120D

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.