Applies to: D5FULA

How to fix coil interface and control box mounting: step by step

  1. Choose the install location, giving priority to the front of the coil; side or nearby wall is acceptable.
  2. Use a flat-head screwdriver at the marked positions to open the control box cover.
  3. Fold the flange up 90 degrees with bending pliers, then fold the flanges around the opening.
  4. Seal all flange sides with tape and insulate with sponge.
  5. Attach the control box with 3 screws into the pre-drilled holes (right or left side).
  6. Use only the supplied screws or equivalent; maximum screw length is 5/8 in (16 mm) to avoid coil damage (see Table 6).
  7. Cut the cover port only as needed for the wires: a single cut for one wire, or cut along the maximum outline for multiple wires.
  8. Close the control box cover.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Handler codes

Source: D5FULA installation instructions, p. 25-26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.