Lennox Error Codes & Diagnostic Codes

Updated · by Aurora Star Tech Inc.

Lennox error codes and diagnostic codes: look up a code to see what it means, the likely causes and the steps to fix it.

Lennox error codes by equipment type

Lennox Air Conditioner error codes

CodeMeaning
10Unknown device detected
11Missing device
12Indoor unit not detected
13Duplicate comfort sensor ID
14Too many devices of the same type
15Parameter mismatch detected
20Protocol upgrade required
21Incompatible equipment detected
29Over temperature protection (indoor above 90 F)
30Low temperature protection (below 40 F)
31Lost communication with device
32Device resetting
34Must program unit capacity for device
35Incorrect operation of device
36Heating when not requested
37Cooling when not requested
38Not heating when requested
39No cooling when requested
41Device control board replaced
611High room temperature detected
700Thermostat temperature sensor problem
701Thermostat temperature above limit
703Thermostat humidity sensor problem
3000Replace filter 1
3001Replace filter 2
3002Replace humidifier pad
3003Replace UV bulb
3004Maintenance reminder
3005PureAir maintenance
65537Missing base (smart hub)
65538Missing base
65539Thermostat lost connection or internal fault
65540Missing HD wall display
65541Firmware download failed
65542Firmware update failed
65543Firmware updated
65544More than 8 thermostats in a group
65545Cooling capacity alert
70001IAQ internal sensor fault
70002IAQ internal data fault
70003IAQ side switch in OFF position
70004Replace Smart IAQ monitor
70501Smart room sensor internal data fault
70502Smart room sensor internal fault
70503Smart room sensor low battery
70504Smart room sensor battery 1%
71001Wireless extender internal data fault
71504Suction temperature sensor incorrect reading
71505Liquid temperature sensor incorrect reading
71506Suction pressure sensor incorrect reading
71507Liquid pressure sensor incorrect reading
71508Outdoor temperature sensor incorrect reading
71510Indoor TXV failure
71512High-pressure switch fault
71513Low-pressure switch fault
71514System low on refrigerant charge
71516Outdoor fan motor failure
71518Compressor failed to start
71520Blocked liquid line
80001IAQ persistent poor air quality
80002Unresponsive wireless device fault
80003Lost communication with wireless device
80005Unknown wireless device found
E105Wiring issue / communication problem
E114AC line frequency / distortion problem
E115Low secondary (24 VAC) voltage
E120Unresponsive device
E124Thermostat lost communication to smart hub
E125Control hardware problem
E126Control internal communication problem
E132Device control software fault
E180Outdoor temperature sensor problem
E181Outdoor suction pressure transducer fault
E182Outdoor suction temperature sensor fault
E183Outdoor liquid pressure sensor fault
E184Outdoor liquid temperature sensor fault
E400Compressor internal overload tripped
E401Compressor long run cycle
E402System pressure trip
E403Compressor short-cycling
E404Compressor rotor locked
E405Compressor open circuit
E406Compressor open start circuit
E407Compressor open run circuit
E408Compressor contactor welded
E409Outdoor control low 24 VAC
E410Open low pressure switch
E411Low pressure switch strikes lockout
E412Open high pressure switch
E413High pressure switch strikes lockout
E414High discharge line temperature
E415High discharge line temperature strikes lockout
E417Discharge sensor faulty
E422Compressor top cap switch open
E423Inverter CT circuit fault (inverter code 40)
E424Liquid line sensor faulty
E426Excessive inverter alarms
E427Inverter DC peak fault (inverter code 21)
E428Inverter high main input current (inverter code 22)
E429Inverter DC link low voltage (inverter code 23)
E430Inverter compressor startup fail (inverter code 26)
E431Inverter PFC fault (inverter code 27)
E432Inverter DC link high voltage (inverter code 28)
E433Inverter compressor over-current (inverter code 29)
E434Inverter communication error to main control (inverter code 53)
E435Inverter EEPROM checksum fault (inverter code 60)
E436Inverter high heat-sink temperature (inverter code 62)
E437Inverter heat-sink temperature sensor fault (inverter code 65)
E438Inverter PFC input over-current (inverter code 73)
E440Inverter compressor slowdown - high heat-sink temperature (inverter code 13)
E441Inverter compressor slowdown - high compressor current (inverter code 14)
E442Compressor top cap switch strikes lockout
E443Unit code to inverter model mismatch
E446Low suction pressure fault
E600Load shed event
E601Low ambient operational lockout

Lennox Air Handler error codes

CodeMeaning
--Double dashes - zone sensor problem
10Unknown device detected
11Missing device
12Indoor unit not detected
13Duplicate comfort sensor ID
14Too many devices of the same type
15Parameter mismatch detected
20Protocol upgrade required
21Incompatible equipment detected
31Lost communication with device
32Device resetting
34Must program unit capacity for device
35Incorrect operation of device
36Heating when not requested
37Cooling when not requested
38Not heating when requested
39No cooling when requested
41Device control board replaced
500PureAir differential pressure sensor fault
501PureAir UV sensor fault
502PureAir UV lamp off
503PureAir filter life at 10%
504PureAir filter life at 0%
505PureAir model selection changed
506PureAir lamp at 0% life
507PureAir filter calibration failure
530Zoning low damper 24 VAC
532Zoning pressure switch opened (high pressure)
542Zone 1 temperature sensor fault
543Zone 2 temperature sensor fault
544Zone 3 temperature sensor fault
545Zone 4 temperature sensor fault
546Zone sensor parameters reset after power restore
547Zone sensor parameters reset from system interruption
548Zone humidity sensor error
551Zone sensor lost communication
71511Duct or filter blockage
71517Indoor fan motor failure
E105Wiring issue / communication problem
E114AC line frequency / distortion problem
E115Low secondary (24 VAC) voltage
E116High secondary (24 VAC) voltage
E117Poor ground
E120Unresponsive device
E124Thermostat lost communication to smart hub
E125Control hardware problem
E126Control internal communication problem
E130Configuration jumper missing
E132Device control software fault
E180Outdoor temperature sensor problem
E201Blower motor communication fault
E202Blower motor and unit size mismatch
E203Invalid unit size code
E292Blower motor start fault
E295Blower motor over temperature
E310Discharge air temperature sensor problem
E312Reduced airflow - indoor blower cutback
E345Relay O failure
E346Heat pump jumper not removed
E347Indoor or EIM relay Y1 fault
E348Indoor relay Y2 fault
E350Electric heat not configured
E351Electric heat stage 1 fault
E352Electric heat stage 2 fault
E353Electric heat stage 3 fault
E354Electric heat stage 4 fault
E355Electric heat stage 5 fault
E371Float switch sensed open
E380EIM interlock relay fault
E381EIM interlock relay stuck
E382EIM relay W1 fault
E420EIM defrost out of cycle

Lennox Furnace error codes

CodeMeaning
--Double dashes - zone sensor problem
1 flashLine voltage polarity reversed
2 flashesImproper earth ground
3 flashesBurner failed to light or lost flame
4 flashesLow flame signal
5 flashesWatchguard - ignition retries/recycles exceeded
7 flashesPrimary or secondary limit open
8 flashesRollout switch open
9 flashesPressure switch stays open or drops out on a heat call
10Unknown device detected
10 flashesWatchguard - pressure switch opened 5 times in one heat demand
11Missing device
11 flashesPressure switch stuck closed before inducer starts
12Indoor unit not detected
12 flashesFlame sensed with gas valve off
13Duplicate comfort sensor ID
13 flashesLow line voltage
14Too many devices of the same type
15Parameter mismatch detected
20Protocol upgrade required
21Incompatible equipment detected
29Over temperature protection (indoor above 90 F)
30Low temperature protection (below 40 F)
31Lost communication with device
32Device resetting
34Must program unit capacity for device
35Incorrect operation of device
36Heating when not requested
37Cooling when not requested
38Not heating when requested
39No cooling when requested
40HP heating lockout
41Device control board replaced
500PureAir differential pressure sensor fault
501PureAir UV sensor fault
502PureAir UV lamp off
503PureAir filter life at 10%
504PureAir filter life at 0%
505PureAir model selection changed
506PureAir lamp at 0% life
507PureAir filter calibration failure
530Zoning low damper 24 VAC
532Zoning pressure switch opened (high pressure)
542Zone 1 temperature sensor fault
543Zone 2 temperature sensor fault
544Zone 3 temperature sensor fault
545Zone 4 temperature sensor fault
546Zone sensor parameters reset after power restore
547Zone sensor parameters reset from system interruption
548Zone humidity sensor error
551Zone sensor lost communication
610Low room temperature detected
700Thermostat temperature sensor problem
701Thermostat temperature above limit
703Thermostat humidity sensor problem
3000Replace filter 1
3001Replace filter 2
3002Replace humidifier pad
3003Replace UV bulb
3004Maintenance reminder
3005PureAir maintenance
65537Missing base (smart hub)
65538Missing base
65539Thermostat lost connection or internal fault
65540Missing HD wall display
65541Firmware download failed
65542Firmware update failed
65543Firmware updated
65544More than 8 thermostats in a group
70001IAQ internal sensor fault
70002IAQ internal data fault
70003IAQ side switch in OFF position
70004Replace Smart IAQ monitor
70501Smart room sensor internal data fault
70502Smart room sensor internal fault
70503Smart room sensor low battery
70504Smart room sensor battery 1%
71001Wireless extender internal data fault
71511Duct or filter blockage
71517Indoor fan motor failure
80001IAQ persistent poor air quality
80002Unresponsive wireless device fault
80003Lost communication with wireless device
80005Unknown wireless device found
E105Device communication problem
E106Twin communication fault
E110Low line voltage
E111Line voltage polarity reversed
E112Ground not detected
E113High line voltage
E114Line frequency out of range
E115Low 24 VAC
E116High 24 VAC
E117Poor ground detected
E120Unresponsive device
E124Lost communication with thermostat
E125Control hardware failure
E126Control internal communication problem
E130Configuration jumper missing
E131Corrupted control parameters
E132Device control software fault
E150A2L refrigerant leak alarm
E151A2L sensor fault
E152Refrigerant leak sensor #2 fault
E154Refrigerant leak sensor #1 communication lost / wrong DIP setting
E155Refrigerant leak sensor #2 communication lost
E160Refrigerant leak sensor #1 wrong type
E161Refrigerant leak sensor #2 wrong type
E163Furnace control board failure
E164Low GWP test mode active
E180Outdoor air temperature sensor failure
E200Flame rollout - hard lockout
E201Indoor blower communication failure
E202Blower motor mismatch
E203Unit capacity not programmed
E204Gas valve miswired
E205Gas valve relay contact shorted
E206Gas valve second-stage relay failure
E207Hot surface ignitor open
E223Low pressure switch failed open
E224Low pressure switch failed closed
E225High pressure switch failed open
E226High pressure switch failed closed
E227Low pressure switch opened during ignition or run
E228Inducer calibration failure
E229Ignition on high fire
E240Low flame current (run mode)
E241Flame sensed out of sequence - flame present
E250Limit switch circuit open
E252Discharge air temperature too high
E270Soft lockout - no flame after max retries
E271Soft lockout - retries exceeded, pressure switch opened
E272Soft lockout - recycles exceeded, pressure switch opened
E273Soft lockout - recycles exceeded, flame failure
E274Soft lockout - limit opened
E275Soft lockout - flame out of sequence, now gone
E276Watchguard calibration failure
E290Ignitor circuit fault
E291Heat airflow below minimum
E292Blower motor will not start
E294Inducer over current
E295Blower motor over temperature
E310Discharge air sensor failure
E311Heat rate reduced for airflow
E312Restricted airflow in cooling/fan
E313Indoor/outdoor capacity mismatch
E331Global network connection problem
E334Y1 relay stuck on control
E344IFC relay Y1 stuck
E345Relay O failure
E347No 24 V on Y1 output
E348No 24 V on Y2 output
E349No 24 V between R and O
E370Interlock switch open
E380EIM interlock relay fault
E381EIM interlock relay stuck
E382EIM relay W1 fault
E390Low GWP relay stuck
E400LSOM - compressor internal overload
E401LSOM - long run or low pressure
E402LSOM - outdoor pressure trip
E403LSOM - compressor short cycling
E404LSOM - locked rotor
E405LSOM - compressor open circuit
E406LSOM - open start circuit
E407LSOM - open run circuit
E408LSOM - welded contactor
E409LSOM - low secondary voltage
Red LED offNo power to control or board fault
Red LED on steadyBoard fault detected (107163-01)

Lennox Heat Pump error codes

CodeMeaning
10Unknown device detected
11Missing device
12Indoor unit not detected
13Duplicate comfort sensor ID
14Too many devices of the same type
15Parameter mismatch detected
20Protocol upgrade required
21Incompatible equipment detected
29Over temperature protection (indoor above 90 F)
30Low temperature protection (below 40 F)
31Lost communication with device
32Device resetting
34Must program unit capacity for device
35Incorrect operation of device
36Heating when not requested
37Cooling when not requested
38Not heating when requested
39No cooling when requested
40HP heating lockout
41Device control board replaced
610Low room temperature detected
611High room temperature detected
700Thermostat temperature sensor problem
701Thermostat temperature above limit
703Thermostat humidity sensor problem
3000Replace filter 1
3001Replace filter 2
3002Replace humidifier pad
3003Replace UV bulb
3004Maintenance reminder
3005PureAir maintenance
65537Missing base (smart hub)
65538Missing base
65539Thermostat lost connection or internal fault
65540Missing HD wall display
65541Firmware download failed
65542Firmware update failed
65543Firmware updated
65544More than 8 thermostats in a group
65545Cooling capacity alert
70001IAQ internal sensor fault
70002IAQ internal data fault
70003IAQ side switch in OFF position
70004Replace Smart IAQ monitor
70501Smart room sensor internal data fault
70502Smart room sensor internal fault
70503Smart room sensor low battery
70504Smart room sensor battery 1%
71001Wireless extender internal data fault
71504Suction temperature sensor incorrect reading
71505Liquid temperature sensor incorrect reading
71506Suction pressure sensor incorrect reading
71507Liquid pressure sensor incorrect reading
71508Outdoor temperature sensor incorrect reading
71509Outdoor coil temperature sensor incorrect reading
71510Indoor TXV failure
71512High-pressure switch fault
71513Low-pressure switch fault
71514System low on refrigerant charge
71515Reversing valve stuck
71516Outdoor fan motor failure
71518Compressor failed to start
71519Incorrect reversing valve mode
71520Blocked liquid line
71521Outdoor TXV failure
80001IAQ persistent poor air quality
80002Unresponsive wireless device fault
80003Lost communication with wireless device
80005Unknown wireless device found
E105Wiring issue / communication problem
E114AC line frequency / distortion problem
E115Low secondary (24 VAC) voltage
E120Unresponsive device
E124Thermostat lost communication to smart hub
E125Control hardware problem
E126Control internal communication problem
E132Device control software fault
E180Outdoor temperature sensor problem
E181Outdoor suction pressure transducer fault
E182Outdoor suction temperature sensor fault
E183Outdoor liquid pressure sensor fault
E184Outdoor liquid temperature sensor fault
E345Relay O failure
E400Compressor internal overload tripped
E401Compressor long run cycle
E402System pressure trip
E403Compressor short-cycling
E404Compressor rotor locked
E405Compressor open circuit
E406Compressor open start circuit
E407Compressor open run circuit
E408Compressor contactor welded
E409Outdoor control low 24 VAC
E410Open low pressure switch
E411Low pressure switch strikes lockout
E412Open high pressure switch
E413High pressure switch strikes lockout
E414High discharge line temperature
E415High discharge line temperature strikes lockout
E416Outdoor coil sensor faulty
E417Discharge sensor faulty
E418EIM W output hardware fault
E419EIM W output hardware fault lockout
E420EIM defrost out of cycle
E421EIM W external miswire fault
E422Compressor top cap switch open
E423Inverter CT circuit fault (inverter code 40)
E424Liquid line sensor faulty
E426Excessive inverter alarms
E427Inverter DC peak fault (inverter code 21)
E428Inverter high main input current (inverter code 22)
E429Inverter DC link low voltage (inverter code 23)
E430Inverter compressor startup fail (inverter code 26)
E431Inverter PFC fault (inverter code 27)
E432Inverter DC link high voltage (inverter code 28)
E433Inverter compressor over-current (inverter code 29)
E434Inverter communication error to main control (inverter code 53)
E435Inverter EEPROM checksum fault (inverter code 60)
E436Inverter high heat-sink temperature (inverter code 62)
E437Inverter heat-sink temperature sensor fault (inverter code 65)
E438Inverter PFC input over-current (inverter code 73)
E440Inverter compressor slowdown - high heat-sink temperature (inverter code 13)
E441Inverter compressor slowdown - high compressor current (inverter code 14)
E442Compressor top cap switch strikes lockout
E443Unit code to inverter model mismatch
E444Reversing valve relay or solenoid fault
E446Low suction pressure fault
E600Load shed event
E601Low ambient operational lockout
Green & Red alternating FAST flashCoil (defrost) sensor problem
Green & Red alternating SLOW flash5-minute anti-short-cycle delay
Green & Red simultaneous FAST flashAmbient (outdoor air) sensor problem
Green FAST flash / Red OFFDischarge sensor lockout
Green FAST flash / Red ONDischarge line temperature lockout
Green OFF / Red FAST flashDischarge sensor fault
Green OFF / Red OFFNo power to the demand defrost control
Green OFF / Red ONLow pressure lockout
Green OFF / Red SLOW flashLow pressure fault
Green ON / Red OFFHigh pressure lockout
Green ON / Red ONDemand defrost control failure
Green SLOW flash / Red OFFHigh pressure fault
Green SLOW flash / Red ONDischarge line temperature fault

Find codes by Lennox model

Lennox EL16KC1

EL16KC1-018-230AEL16KC1-024-230AEL16KC1-030-230AEL16KC1-036-230AEL16KC1-041-230AEL16KC1-042-230AEL16KC1-047-230AEL16KC1-048-230AEL16KC1-060-230A

Lennox EL16KP1

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060

Lennox EL195UHNE

EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C

EL296UHV

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60D

Lennox ML14KP1

ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Lennox ML180UHE

ML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DK

Lennox SL280UHV

SL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60D

Lennox SL297NV

SL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.