Lennox Error Code E120: Unresponsive device (Heat Pump)

Updated · by Aurora Star Tech Inc.

Lennox error code E120 on a heat pump means: Unresponsive device. It is also called Lennox diagnostic code E120.

Medium severityHeat Pump

Homeowner? What Lennox code E120 means for you

Check, then call Your heat pump is reporting: Unresponsive device. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E120 mean?

A component is slow to respond to the system, usually the outdoor unit answering the thermostat; often harmless and clears by itself. S30/S40 thermostat alert code 120 (shown as E120 on the unit control display).

Applies to: Lennox communicating heat pumps incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code E120

  • Slow outdoor unit response
  • Voltage leaking between strands in the cable bundle
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E120

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Other Lennox Heat Pump codes

CodeMeaning
80005Unknown wireless device found
=Two bars - soft disable
Amber lightEmergency heat indicator (thermostat)
E105Wiring issue / communication problem
E114AC line frequency / distortion problem
E115Low secondary (24 VAC) voltage
E124Thermostat lost communication to smart hub
E125Control hardware problem
E126Control internal communication problem
E132Device control software fault
E180Outdoor temperature sensor problem
E181Outdoor suction pressure transducer fault

All Lennox Heat Pump error codes →

Lennox code E120: homeowner questions

What does Lennox code E120 mean?

Unresponsive device. A component is slow to respond to the system, usually the outdoor unit answering the thermostat; often harmless and clears by itself. S30/S40 thermostat alert code 120 (shown as E120 on the unit control display).

Is it safe to keep using my heat pump with code E120?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Lennox code E120 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E120 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E120 near me?

Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.