Lennox Error Code E105: Wiring issue / communication problem (Heat Pump)

Updated · by Aurora Star Tech Inc.

Lennox error code E105 on a heat pump means: Wiring issue / communication problem. It is also called Lennox diagnostic code E105.

High severityHeat Pump

Homeowner? What Lennox code E105 means for you

Call a technician Your heat pump is reporting: Wiring issue / communication problem. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E105 mean?

Low-voltage wiring between components is compromised and a device cannot communicate (RSBus message errors, usually electrical noise). S30/S40 thermostat alert code 105 (shown as E105 on the unit control display).

Applies to: Lennox communicating heat pumps incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code E105

  • Unused thermostat wires left floating
  • Loose terminals or poor splices
  • Low-voltage wiring run beside high-voltage wiring

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E105

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Other Lennox Heat Pump codes

CodeMeaning
71521Outdoor TXV failure
80001IAQ persistent poor air quality
80002Unresponsive wireless device fault
80005Unknown wireless device found
=Two bars - soft disable
Amber lightEmergency heat indicator (thermostat)
E114AC line frequency / distortion problem
E115Low secondary (24 VAC) voltage
E120Unresponsive device
E124Thermostat lost communication to smart hub
E125Control hardware problem
E126Control internal communication problem

All Lennox Heat Pump error codes →

Lennox code E105: homeowner questions

What does Lennox code E105 mean?

Wiring issue / communication problem. Low-voltage wiring between components is compromised and a device cannot communicate (RSBus message errors, usually electrical noise). S30/S40 thermostat alert code 105 (shown as E105 on the unit control display).

Is it safe to keep using my heat pump with code E105?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code E105 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E105 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E105 near me?

Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.14. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.