Lennox Air Handler Error Codes

Updated · by Aurora Star Tech Inc.

72 Lennox Air Handler error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Lennox Air Handler error codes list

CodeMeaningSeverity
--Double dashes - zone sensor problemMedium
10Unknown device detectedHigh
11Missing deviceHigh
12Indoor unit not detectedHigh
13Duplicate comfort sensor IDHigh
14Too many devices of the same typeHigh
15Parameter mismatch detectedLow
20Protocol upgrade requiredHigh
21Incompatible equipment detectedHigh
31Lost communication with deviceHigh
32Device resettingLow
34Must program unit capacity for deviceHigh
35Incorrect operation of deviceHigh
36Heating when not requestedHigh
37Cooling when not requestedHigh
38Not heating when requestedHigh
39No cooling when requestedHigh
41Device control board replacedLow
500PureAir differential pressure sensor faultMedium
501PureAir UV sensor faultMedium
502PureAir UV lamp offMedium
503PureAir filter life at 10%Medium
504PureAir filter life at 0%Medium
505PureAir model selection changedMedium
506PureAir lamp at 0% lifeMedium
507PureAir filter calibration failureMedium
530Zoning low damper 24 VACMedium
532Zoning pressure switch opened (high pressure)Low
542Zone 1 temperature sensor faultMedium
543Zone 2 temperature sensor faultMedium
544Zone 3 temperature sensor faultMedium
545Zone 4 temperature sensor faultMedium
546Zone sensor parameters reset after power restoreMedium
547Zone sensor parameters reset from system interruptionMedium
548Zone humidity sensor errorMedium
551Zone sensor lost communicationMedium
71511Duct or filter blockageMedium
71517Indoor fan motor failureHigh
E105Wiring issue / communication problemHigh
E114AC line frequency / distortion problemHigh
E115Low secondary (24 VAC) voltageHigh
E116High secondary (24 VAC) voltageMedium
E117Poor groundMedium
E120Unresponsive deviceMedium
E124Thermostat lost communication to smart hubHigh
E125Control hardware problemHigh
E126Control internal communication problemHigh
E130Configuration jumper missingHigh
E132Device control software faultHigh
E180Outdoor temperature sensor problemMedium
E201Blower motor communication faultHigh
E202Blower motor and unit size mismatchHigh
E203Invalid unit size codeHigh
E292Blower motor start faultHigh
E295Blower motor over temperatureMedium
E310Discharge air temperature sensor problemMedium
E312Reduced airflow - indoor blower cutbackLow
E345Relay O failureHigh
E346Heat pump jumper not removedHigh
E347Indoor or EIM relay Y1 faultHigh
E348Indoor relay Y2 faultMedium
E350Electric heat not configuredHigh
E351Electric heat stage 1 faultHigh
E352Electric heat stage 2 faultMedium
E353Electric heat stage 3 faultMedium
E354Electric heat stage 4 faultMedium
E355Electric heat stage 5 faultMedium
E371Float switch sensed openHigh
E380EIM interlock relay faultHigh
E381EIM interlock relay stuckHigh
E382EIM relay W1 faultHigh
E420EIM defrost out of cycleMedium

Air Handler troubleshooting guides

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.