Lennox SL280UH060NV36A error codes list

CodeMeaningSeverity
--Double dashes - zone sensor problemMedium
10Unknown device detectedHigh
11Missing deviceHigh
12Indoor unit not detectedHigh
13Duplicate comfort sensor IDHigh
14Too many devices of the same typeHigh
15Parameter mismatch detectedLow
20Protocol upgrade requiredHigh
21Incompatible equipment detectedHigh
29Over temperature protection (indoor above 90 F)High
30Low temperature protection (below 40 F)High
31Lost communication with deviceHigh
32Device resettingLow
34Must program unit capacity for deviceHigh
35Incorrect operation of deviceHigh
36Heating when not requestedHigh
37Cooling when not requestedHigh
38Not heating when requestedHigh
39No cooling when requestedHigh
40HP heating lockoutLow
41Device control board replacedLow
500PureAir differential pressure sensor faultMedium
501PureAir UV sensor faultMedium
502PureAir UV lamp offMedium
503PureAir filter life at 10%Medium
504PureAir filter life at 0%Medium
505PureAir model selection changedMedium
506PureAir lamp at 0% lifeMedium
507PureAir filter calibration failureMedium
530Zoning low damper 24 VACMedium
532Zoning pressure switch opened (high pressure)Low
542Zone 1 temperature sensor faultMedium
543Zone 2 temperature sensor faultMedium
544Zone 3 temperature sensor faultMedium
545Zone 4 temperature sensor faultMedium
546Zone sensor parameters reset after power restoreMedium
547Zone sensor parameters reset from system interruptionMedium
548Zone humidity sensor errorMedium
551Zone sensor lost communicationMedium
610Low room temperature detectedHigh
700Thermostat temperature sensor problemHigh
701Thermostat temperature above limitHigh
703Thermostat humidity sensor problemMedium
3000Replace filter 1Low
3001Replace filter 2Low
3002Replace humidifier padLow
3003Replace UV bulbLow
3004Maintenance reminderLow
3005PureAir maintenanceLow
65537Missing base (smart hub)High
65538Missing baseLow
65539Thermostat lost connection or internal faultHigh
65540Missing HD wall displayLow
65541Firmware download failedLow
65542Firmware update failedLow
65543Firmware updatedLow
65544More than 8 thermostats in a groupLow
70001IAQ internal sensor faultMedium
70002IAQ internal data faultMedium
70003IAQ side switch in OFF positionHigh
70004Replace Smart IAQ monitorMedium
70501Smart room sensor internal data faultMedium
70502Smart room sensor internal faultMedium
70503Smart room sensor low batteryLow
70504Smart room sensor battery 1%Low
71001Wireless extender internal data faultMedium
71511Duct or filter blockageMedium
71517Indoor fan motor failureHigh
80001IAQ persistent poor air qualityLow
80002Unresponsive wireless device faultLow
80003Lost communication with wireless deviceMedium
80005Unknown wireless device foundMedium
E105Device communication problemHigh
E110Low line voltageHigh
E111Line voltage polarity reversedHigh
E112Ground not detectedHigh
E113High line voltageHigh
E114Line frequency out of rangeHigh
E115Low 24 VACHigh
E116High 24 VACHigh
E117Poor ground detectedMedium
E120Unresponsive deviceMedium
E124Lost communication with thermostatHigh
E125Control hardware failureCritical
E126Control internal communication problemHigh
E130Configuration jumper missingHigh
E131Corrupted control parametersHigh
E132Device control software faultHigh
E150A2L refrigerant leak alarmCritical
E151A2L sensor faultHigh
E180Outdoor air temperature sensor failureMedium
E200Flame rollout - hard lockoutCritical
E201Indoor blower communication failureHigh
E202Blower motor mismatchHigh
E203Unit capacity not programmedCritical
E204Gas valve miswiredHigh
E205Gas valve relay contact shortedCritical
E206Gas valve second-stage relay failureMedium
E207Hot surface ignitor openHigh
E223Low pressure switch failed openHigh
E224Low pressure switch failed closedHigh
E225High pressure switch failed openHigh
E226High pressure switch failed closedHigh
E227Low pressure switch opened during ignition or runHigh
E228Inducer calibration failureMedium
E229Ignition on high fireLow
E240Low flame current (run mode)Medium
E241Flame sensed out of sequence - flame presentCritical
E250Limit switch circuit openHigh
E252Discharge air temperature too highMedium
E270Soft lockout - no flame after max retriesHigh
E271Soft lockout - retries exceeded, pressure switch openedHigh
E272Soft lockout - recycles exceeded, pressure switch openedHigh
E273Soft lockout - recycles exceeded, flame failureHigh
E274Soft lockout - limit openedHigh
E275Soft lockout - flame out of sequence, now goneCritical
E276Watchguard calibration failureHigh
E290Ignitor circuit faultHigh
E291Heat airflow below minimumHigh
E292Blower motor will not startHigh
E294Inducer over currentHigh
E295Blower motor over temperatureHigh
E310Discharge air sensor failureMedium
E311Heat rate reduced for airflowMedium
E312Restricted airflow in cooling/fanMedium
E313Indoor/outdoor capacity mismatchLow
E331Global network connection problemLow
E334Y1 relay stuck on controlHigh
E344IFC relay Y1 stuckHigh
E345Relay O failureHigh
E347No 24 V on Y1 outputCritical
E348No 24 V on Y2 outputCritical
E349No 24 V between R and OCritical
E370Interlock switch openHigh
E380EIM interlock relay faultHigh
E381EIM interlock relay stuckHigh
E382EIM relay W1 faultHigh
E400LSOM - compressor internal overloadHigh
E401LSOM - long run or low pressureCritical
E402LSOM - outdoor pressure tripHigh
E403LSOM - compressor short cyclingMedium
E404LSOM - locked rotorHigh
E405LSOM - compressor open circuitHigh
E406LSOM - open start circuitHigh
E407LSOM - open run circuitHigh
E408LSOM - welded contactorHigh
E409LSOM - low secondary voltageHigh

Troubleshooting the SL280UH060NV36A

All Lennox Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.