Lennox Error Code 71518: Compressor failed to start (Heat Pump)
Lennox error code 71518 on a heat pump means: Compressor failed to start. It is also called Lennox diagnostic code 71518.
Homeowner? What Lennox code 71518 means for you
Call a technician Your heat pump is reporting: Compressor failed to start. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Lennox error code 71518 mean?
Liquid to suction pressure ratio outside the expected range. (S40 system diagnostics) S30/S40 thermostat alert code 71518.
Applies to: Lennox communicating heat pumps incl. variable-capacity inverter units in S30/S40 smart thermostat systems
Common causes of Lennox code 71518
- See description
Lennox models that use code 71518
EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060
Other Lennox Heat Pump codes
All Lennox Heat Pump error codes →
Lennox code 71518: homeowner questions
What does Lennox code 71518 mean?
Compressor failed to start. Liquid to suction pressure ratio outside the expected range. (S40 system diagnostics) S30/S40 thermostat alert code 71518.
Is it safe to keep using my heat pump with code 71518?
It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Lennox code 71518 myself?
You can try one reset (power off for 30 seconds, then on). If Lennox code 71518 comes back, the cause is still there and a licensed technician should check it.
Who can fix Lennox code 71518 near me?
Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- Heat pump not defrosting / outdoor coil iced - Lennox EL16KP1 / ML14KP1 Lennox · Heat Pump
- Low capacity or abnormal pressures - Lennox EL16KP1 / ML14KP1 Lennox · Heat Pump
- Outdoor unit will not start - Lennox EL16KP1 / ML14KP1 Lennox · Heat Pump
- Two horizontal lines on display (soft disable) - Lennox communicating Lennox · Heat Pump
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.50. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.