Lennox Error Code E290: Ignitor circuit fault (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code E290 on a furnace means: Ignitor circuit fault. It is also called Lennox diagnostic code E290.

High severityFurnaceEL296UHV · Lennox SL280UHV · Lennox ML180UHE · Lennox SL297NV

Homeowner? What Lennox code E290 means for you

Call a technician Your furnace is reporting: Ignitor circuit fault. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E290 mean?

Failed ignitor or ignitor drive circuit; 1-hour soft lockout.

Applies to: EL296UHV(X) series furnaces (integrated control 103130-XX and 107045-XX)

Common causes of Lennox code E290

  • Failed ignitor
  • Wiring fault
  • Control ignitor circuit failure
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E290

Show all 34 models

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60DML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DKSL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60DSL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Other Lennox Furnace codes

CodeMeaning
E271Soft lockout - retries exceeded, pressure switch opened
E272Soft lockout - recycles exceeded, pressure switch opened
E273Soft lockout - recycles exceeded, flame failure
E274Soft lockout - limit opened
E275Soft lockout - flame out of sequence, now gone
E276Watchguard calibration failure
E291Heat airflow below minimum
E292Blower motor will not start
E294Inducer over current
E295Blower motor over temperature
E310Discharge air sensor failure
E311Heat rate reduced for airflow

All Lennox Furnace error codes →

Lennox code E290: homeowner questions

What does Lennox code E290 mean?

Ignitor circuit fault. Failed ignitor or ignitor drive circuit; 1-hour soft lockout.

Is it safe to keep using my furnace with code E290?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code E290 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E290 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E290 near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox EL296UHV(X) Unit Information / Service Literature, Table 5 Ignition Control 103130-XX Diagnostic Codes, p.36; Ignition Control 107045-XX Diagnostic Codes table, p.43, Unit Components p.54, Proper Ground and Voltage p.85. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.