Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Error Code E313: Indoor/outdoor capacity mismatch (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code E313 on a furnace means: Indoor/outdoor capacity mismatch. It is also called Lennox diagnostic code E313.

Low severityFurnaceEL296UHV · Lennox SL280UHV · Lennox SL297NV

Homeowner? What Lennox code E313 means for you

Usually minor Your furnace is reporting: Indoor/outdoor capacity mismatch. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E313 mean?

Communicating only. Incorrect indoor/outdoor capacity code; system runs but may not meet capacity or efficiency.

Applies to: EL296UHV(X) series furnaces (integrated control 103130-XX and 107045-XX)

Common causes of Lennox code E313

  • Wrong capacity code selected
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E313

Show all 22 models

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60DSL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60DSL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Other Lennox Furnace codes

CodeMeaning
E292Blower motor will not start
E294Inducer over current
E295Blower motor over temperature
E310Discharge air sensor failure
E311Heat rate reduced for airflow
E312Restricted airflow in cooling/fan
E331Global network connection problem
E334Y1 relay stuck on control
E344IFC relay Y1 stuck
E345Relay O failure
E347No 24 V on Y1 output
E348No 24 V on Y2 output

All Lennox Furnace error codes →

Lennox code E313: homeowner questions

What does Lennox code E313 mean?

Indoor/outdoor capacity mismatch. Communicating only. Incorrect indoor/outdoor capacity code; system runs but may not meet capacity or efficiency.

Is it safe to keep using my furnace with code E313?

Usually yes. Code E313 is normally minor, but if it keeps coming back have it checked.

Can I reset Lennox code E313 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E313 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E313 near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox EL296UHV(X) Unit Information / Service Literature, Table 5 Ignition Control 103130-XX Diagnostic Codes, p.37; Ignition Control 107045-XX Diagnostic Codes table, p.44. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977