Lennox Error Code E433: Inverter compressor over-current (inverter code 29) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Lennox error code E433 on a heat pump means: Inverter compressor over-current (inverter code 29). It is also called Lennox diagnostic code E433.

High severityHeat Pump

Homeowner? What Lennox code E433 means for you

Call a technician Your heat pump is reporting: Inverter compressor over-current (inverter code 29). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E433 mean?

Compressor peak phase current above 28 A (six-minute delay at startup). The inverter first slows down (code 14); if current stays high the unit stops. Five times in 60 minutes = lockout. The outdoor control can also trigger 433 if speed falls below minimum at startup. Inverter LED flash code 29 (red 2 flashes, green 9 flashes). S30/S40 thermostat alert code 433 (shown as E433 on the unit control display).

Applies to: Lennox communicating heat pumps incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code E433

  • High load or pressure
  • Older outdoor control software
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E433

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Other Lennox Heat Pump codes

CodeMeaning
E427Inverter DC peak fault (inverter code 21)
E428Inverter high main input current (inverter code 22)
E429Inverter DC link low voltage (inverter code 23)
E430Inverter compressor startup fail (inverter code 26)
E431Inverter PFC fault (inverter code 27)
E432Inverter DC link high voltage (inverter code 28)
E434Inverter communication error to main control (inverter code 53)
E435Inverter EEPROM checksum fault (inverter code 60)
E436Inverter high heat-sink temperature (inverter code 62)
E437Inverter heat-sink temperature sensor fault (inverter code 65)
E438Inverter PFC input over-current (inverter code 73)
E440Inverter compressor slowdown - high heat-sink temperature (inverter code 13)

All Lennox Heat Pump error codes →

Lennox code E433: homeowner questions

What does Lennox code E433 mean?

Inverter compressor over-current (inverter code 29). Compressor peak phase current above 28 A (six-minute delay at startup). The inverter first slows down (code 14); if current stays high the unit stops. Five times in 60 minutes = lockout. The outdoor control can also trigger 433 if speed…

Is it safe to keep using my heat pump with code E433?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code E433 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E433 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E433 near me?

Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.38. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977