Lennox Error Code 9 flashes: Pressure switch stays open or drops out on a heat call (Furnace)
Lennox error code 9 flashes on a furnace means: Pressure switch stays open or drops out on a heat call. It is also called Lennox diagnostic code 9 flashes.
Homeowner? What Lennox code 9 flashes means for you
Call a technician Your furnace is reporting: Pressure switch stays open or drops out on a heat call. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Lennox error code 9 flashes mean?
The combustion air pressure switch did not prove within 2-1/2 minutes, or opened while running. The control goes into a 5-minute pressure switch Watchguard.
Applies to: EL195UHNE furnaces with ignition control 103217-03 or 107163-01 (red LED)
Common causes of Lennox code 9 flashes
- Blocked or too-long vent/intake
- Plugged condensate drain or trap backing water into the header box
- Kinked, cracked or plugged pressure switch hoses or hose screens
A technician checks these and 2 other possible causes on site before replacing any part.
Lennox models that use code 9 flashes
EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C
Other Lennox Furnace codes
All Lennox Furnace error codes →
Lennox code 9 flashes: homeowner questions
What does Lennox code 9 flashes mean?
Pressure switch stays open or drops out on a heat call. The combustion air pressure switch did not prove within 2-1/2 minutes, or opened while running. The control goes into a 5-minute pressure switch Watchguard.
Is it safe to keep using my furnace with code 9 flashes?
It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Lennox code 9 flashes myself?
You can try one reset (power off for 30 seconds, then on). If Lennox code 9 flashes comes back, the cause is still there and a licensed technician should check it.
Who can fix Lennox code 9 flashes near me?
Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: Lennox EL195UHNE Unit Information Corp 1801-L1 (rev 04/2024), Table 4 (103217-03) / Table 5 (107163-01) diagnostic codes, p.8-10; Table 8, p.14; maintenance p.47-48. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.