Lennox Error Code E437: Inverter heat-sink temperature sensor fault (inverter code 65) (AC)

Updated · by Aurora Star Tech Inc.

Lennox error code E437 on a air conditioner means: Inverter heat-sink temperature sensor fault (inverter code 65). It is also called Lennox diagnostic code E437.

High severityAir ConditionerAlso Heat Pump

Homeowner? What Lennox code E437 means for you

Call a technician Your air conditioner is reporting: Inverter heat-sink temperature sensor fault (inverter code 65). The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E437 mean?

Heat sink sensor reads below 4 F or above 264 F after 10 minutes of operation; unit stops. Five times in an hour = lockout. Inverter LED flash code 65 (red 6 flashes, green 5 flashes). S30/S40 thermostat alert code 437 (shown as E437 on the unit control display).

Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code E437

  • Failed heat sink sensor / inverter
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E437

EL16KC1-018-230AEL16KC1-024-230AEL16KC1-030-230AEL16KC1-036-230AEL16KC1-041-230AEL16KC1-042-230AEL16KC1-047-230AEL16KC1-048-230AEL16KC1-060-230A

Other Lennox AC codes

CodeMeaning
E431Inverter PFC fault (inverter code 27)
E432Inverter DC link high voltage (inverter code 28)
E433Inverter compressor over-current (inverter code 29)
E434Inverter communication error to main control (inverter code 53)
E435Inverter EEPROM checksum fault (inverter code 60)
E436Inverter high heat-sink temperature (inverter code 62)
E438Inverter PFC input over-current (inverter code 73)
E440Inverter compressor slowdown - high heat-sink temperature (inverter code 13)
E441Inverter compressor slowdown - high compressor current (inverter code 14)
E442Compressor top cap switch strikes lockout
E443Unit code to inverter model mismatch
E446Low suction pressure fault

All Lennox Air Conditioner error codes →

Lennox code E437: homeowner questions

What does Lennox code E437 mean?

Inverter heat-sink temperature sensor fault (inverter code 65). Heat sink sensor reads below 4 F or above 264 F after 10 minutes of operation; unit stops. Five times in an hour = lockout. Inverter LED flash code 65 (red 6 flashes, green 5 flashes). S30/S40 thermostat alert code 437 (shown as E437 on…

Is it safe to keep using my air conditioner with code E437?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code E437 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E437 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E437 near me?

Aurora Star Tech Inc. repairs Lennox air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.41. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977