Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox EL195UH080NE48C Error Codes

Updated · by Aurora Star Tech Inc.

Lennox EL195UH080NE48C error codes and diagnostic codes. The EL195UH080NE48C is a Lennox furnace in the Lennox EL195UHNE series.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Lennox EL195UH080NE48C error codes list

CodeMeaningSeverity
--Double dashes - zone sensor problemMedium
1 flashLine voltage polarity reversedMedium
2 flashesImproper earth groundMedium
3 flashesBurner failed to light or lost flameHigh
4 flashesLow flame signalMedium
5 flashesWatchguard - ignition retries/recycles exceededHigh
7 flashesPrimary or secondary limit openHigh
8 flashesRollout switch openCritical
9 flashesPressure switch stays open or drops out on a heat callHigh
10Unknown device detectedHigh
10 flashesWatchguard - pressure switch opened 5 times in one heat demandHigh
11Missing deviceHigh
11 flashesPressure switch stuck closed before inducer startsMedium
12Indoor unit not detectedHigh
12 flashesFlame sensed with gas valve offCritical
13Duplicate comfort sensor IDHigh
13 flashesLow line voltageMedium
14Too many devices of the same typeHigh
15Parameter mismatch detectedLow
20Protocol upgrade requiredHigh
21Incompatible equipment detectedHigh
29Over temperature protection (indoor above 90 F)High
30Low temperature protection (below 40 F)High
31Lost communication with deviceHigh
32Device resettingLow
34Must program unit capacity for deviceHigh
35Incorrect operation of deviceHigh
36Heating when not requestedHigh
37Cooling when not requestedHigh
38Not heating when requestedHigh
39No cooling when requestedHigh
40HP heating lockoutLow
41Device control board replacedLow
500PureAir differential pressure sensor faultMedium
501PureAir UV sensor faultMedium
502PureAir UV lamp offMedium
503PureAir filter life at 10%Medium
504PureAir filter life at 0%Medium
505PureAir model selection changedMedium
506PureAir lamp at 0% lifeMedium
507PureAir filter calibration failureMedium
530Zoning low damper 24 VACMedium
532Zoning pressure switch opened (high pressure)Low
542Zone 1 temperature sensor faultMedium
543Zone 2 temperature sensor faultMedium
544Zone 3 temperature sensor faultMedium
545Zone 4 temperature sensor faultMedium
546Zone sensor parameters reset after power restoreMedium
547Zone sensor parameters reset from system interruptionMedium
548Zone humidity sensor errorMedium
551Zone sensor lost communicationMedium
610Low room temperature detectedHigh
700Thermostat temperature sensor problemHigh
701Thermostat temperature above limitHigh
703Thermostat humidity sensor problemMedium
3000Replace filter 1Low
3001Replace filter 2Low
3002Replace humidifier padLow
3003Replace UV bulbLow
3004Maintenance reminderLow
3005PureAir maintenanceLow
65537Missing base (smart hub)High
65538Missing baseLow
65539Thermostat lost connection or internal faultHigh
65540Missing HD wall displayLow
65541Firmware download failedLow
65542Firmware update failedLow
65543Firmware updatedLow
65544More than 8 thermostats in a groupLow
70001IAQ internal sensor faultMedium
70002IAQ internal data faultMedium
70003IAQ side switch in OFF positionHigh
70004Replace Smart IAQ monitorMedium
70501Smart room sensor internal data faultMedium
70502Smart room sensor internal faultMedium
70503Smart room sensor low batteryLow
70504Smart room sensor battery 1%Low
71001Wireless extender internal data faultMedium
71511Duct or filter blockageMedium
71517Indoor fan motor failureHigh
80001IAQ persistent poor air qualityLow
80002Unresponsive wireless device faultLow
80003Lost communication with wireless deviceMedium
80005Unknown wireless device foundMedium
E130Configuration jumper missingHigh
E132Device control software faultHigh
E344IFC relay Y1 stuckHigh
E380EIM interlock relay faultHigh
E381EIM interlock relay stuckHigh
E382EIM relay W1 faultHigh
Red LED offNo power to control or board faultHigh
Red LED on steadyBoard fault detected (107163-01)High

Troubleshooting the EL195UH080NE48C

Lennox EL195UH080NE48C specs and setup data

All Lennox Furnace error codes →

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977