Lennox Error Code 548: Zone humidity sensor error (Air Handler)

Updated · by Aurora Star Tech Inc.

Lennox error code 548 on a air handler means: Zone humidity sensor error. It is also called Lennox diagnostic code 548.

Medium severityAir HandlerAlso Furnace

Homeowner? What Lennox code 548 means for you

Check, then call Your air handler is reporting: Zone humidity sensor error. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code 548 mean?

Humidity sensor reads outside 0-100% (sensor malfunction). S30/S40 thermostat alert code 548.

Applies to: Lennox communicating air handlers and EIM-equipped indoor units in S30/S40 smart thermostat systems

Common causes of Lennox code 548

  • Failed humidity sensor
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Lennox Air Handler codes

CodeMeaning
542Zone 1 temperature sensor fault
543Zone 2 temperature sensor fault
544Zone 3 temperature sensor fault
545Zone 4 temperature sensor fault
546Zone sensor parameters reset after power restore
547Zone sensor parameters reset from system interruption
551Zone sensor lost communication
71511Duct or filter blockage
71517Indoor fan motor failure
E105Wiring issue / communication problem
E114AC line frequency / distortion problem
E115Low secondary (24 VAC) voltage

All Lennox Air Handler error codes →

Lennox code 548: homeowner questions

What does Lennox code 548 mean?

Zone humidity sensor error. Humidity sensor reads outside 0-100% (sensor malfunction). S30/S40 thermostat alert code 548.

Is it safe to keep using my air handler with code 548?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Lennox code 548 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code 548 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code 548 near me?

Aurora Star Tech Inc. repairs Lennox air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.45. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.