Lennox EL16KC1-024-230A Error Codes

Updated · by Aurora Star Tech Inc.

Lennox EL16KC1-024-230A error codes and diagnostic codes (also listed as EL16KC1-024-230A01, EL16KC1-024-230A02, EL16KC1-024). The EL16KC1-024-230A is a Lennox air conditioner in the Lennox EL16KC1 series.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Lennox EL16KC1-024-230A error codes list

CodeMeaningSeverity
10Unknown device detectedHigh
11Missing deviceHigh
12Indoor unit not detectedHigh
13Duplicate comfort sensor IDHigh
14Too many devices of the same typeHigh
15Parameter mismatch detectedLow
20Protocol upgrade requiredHigh
21Incompatible equipment detectedHigh
29Over temperature protection (indoor above 90 F)High
30Low temperature protection (below 40 F)High
31Lost communication with deviceHigh
32Device resettingLow
34Must program unit capacity for deviceHigh
35Incorrect operation of deviceHigh
36Heating when not requestedHigh
37Cooling when not requestedHigh
38Not heating when requestedHigh
39No cooling when requestedHigh
41Device control board replacedLow
611High room temperature detectedHigh
700Thermostat temperature sensor problemHigh
701Thermostat temperature above limitHigh
703Thermostat humidity sensor problemMedium
3000Replace filter 1Low
3001Replace filter 2Low
3002Replace humidifier padLow
3003Replace UV bulbLow
3004Maintenance reminderLow
3005PureAir maintenanceLow
65537Missing base (smart hub)High
65538Missing baseLow
65539Thermostat lost connection or internal faultHigh
65540Missing HD wall displayLow
65541Firmware download failedLow
65542Firmware update failedLow
65543Firmware updatedLow
65544More than 8 thermostats in a groupLow
65545Cooling capacity alertMedium
70001IAQ internal sensor faultMedium
70002IAQ internal data faultMedium
70003IAQ side switch in OFF positionHigh
70004Replace Smart IAQ monitorMedium
70501Smart room sensor internal data faultMedium
70502Smart room sensor internal faultMedium
70503Smart room sensor low batteryLow
70504Smart room sensor battery 1%Low
71001Wireless extender internal data faultMedium
71504Suction temperature sensor incorrect readingLow
71505Liquid temperature sensor incorrect readingLow
71506Suction pressure sensor incorrect readingLow
71507Liquid pressure sensor incorrect readingLow
71508Outdoor temperature sensor incorrect readingLow
71510Indoor TXV failureMedium
71512High-pressure switch faultHigh
71513Low-pressure switch faultMedium
71514System low on refrigerant chargeMedium
71516Outdoor fan motor failureHigh
71518Compressor failed to startHigh
71520Blocked liquid lineHigh
80001IAQ persistent poor air qualityLow
80002Unresponsive wireless device faultLow
80003Lost communication with wireless deviceMedium
80005Unknown wireless device foundMedium
E105Wiring issue / communication problemHigh
E114AC line frequency / distortion problemHigh
E115Low secondary (24 VAC) voltageHigh
E120Unresponsive deviceMedium
E124Thermostat lost communication to smart hubHigh
E125Control hardware problemHigh
E126Control internal communication problemHigh
E132Device control software faultHigh
E180Outdoor temperature sensor problemMedium
E181Outdoor suction pressure transducer faultMedium
E182Outdoor suction temperature sensor faultMedium
E183Outdoor liquid pressure sensor faultMedium
E184Outdoor liquid temperature sensor faultMedium
E400Compressor internal overload trippedMedium
E401Compressor long run cycleLow
E402System pressure tripMedium
E403Compressor short-cyclingMedium
E404Compressor rotor lockedHigh
E405Compressor open circuitHigh
E406Compressor open start circuitHigh
E407Compressor open run circuitHigh
E408Compressor contactor weldedHigh
E409Outdoor control low 24 VACMedium
E410Open low pressure switchLow
E411Low pressure switch strikes lockoutHigh
E412Open high pressure switchLow
E413High pressure switch strikes lockoutHigh
E414High discharge line temperatureMedium
E415High discharge line temperature strikes lockoutHigh
E417Discharge sensor faultyMedium
E422Compressor top cap switch openMedium
E423Inverter CT circuit fault (inverter code 40)High
E424Liquid line sensor faultyMedium
E426Excessive inverter alarmsHigh
E427Inverter DC peak fault (inverter code 21)High
E428Inverter high main input current (inverter code 22)High
E429Inverter DC link low voltage (inverter code 23)High
E430Inverter compressor startup fail (inverter code 26)High
E431Inverter PFC fault (inverter code 27)High
E432Inverter DC link high voltage (inverter code 28)High
E433Inverter compressor over-current (inverter code 29)High
E434Inverter communication error to main control (inverter code 53)High
E435Inverter EEPROM checksum fault (inverter code 60)High
E436Inverter high heat-sink temperature (inverter code 62)High
E437Inverter heat-sink temperature sensor fault (inverter code 65)High
E438Inverter PFC input over-current (inverter code 73)High
E440Inverter compressor slowdown - high heat-sink temperature (inverter code 13)Low
E441Inverter compressor slowdown - high compressor current (inverter code 14)Low
E442Compressor top cap switch strikes lockoutHigh
E443Unit code to inverter model mismatchHigh
E446Low suction pressure faultHigh
E600Load shed eventLow
E601Low ambient operational lockoutLow

Troubleshooting the EL16KC1-024-230A

Lennox EL16KC1-024-230A specs and setup data

All Lennox Air Conditioner error codes →

Homeowner help: AC Running But Not Cooling: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.