Lennox Error Code 504: PureAir filter life at 0% (Air Handler)

Updated · by Aurora Star Tech Inc.

Lennox error code 504 on a air handler means: PureAir filter life at 0%. It is also called Lennox diagnostic code 504.

Medium severityAir HandlerAlso Furnace

Homeowner? What Lennox code 504 means for you

Check, then call Your air handler is reporting: PureAir filter life at 0%. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code 504 mean?

Filter life remaining is 0%. S30/S40 thermostat alert code 504.

Applies to: Lennox communicating air handlers and EIM-equipped indoor units in S30/S40 smart thermostat systems

Common causes of Lennox code 504

  • PureAir S accessory issue
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Lennox Air Handler codes

CodeMeaning
39No cooling when requested
41Device control board replaced
500PureAir differential pressure sensor fault
501PureAir UV sensor fault
502PureAir UV lamp off
503PureAir filter life at 10%
505PureAir model selection changed
506PureAir lamp at 0% life
507PureAir filter calibration failure
530Zoning low damper 24 VAC
532Zoning pressure switch opened (high pressure)
542Zone 1 temperature sensor fault

All Lennox Air Handler error codes →

Lennox code 504: homeowner questions

What does Lennox code 504 mean?

PureAir filter life at 0%. Filter life remaining is 0%. S30/S40 thermostat alert code 504.

Is it safe to keep using my air handler with code 504?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Lennox code 504 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code 504 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code 504 near me?

Aurora Star Tech Inc. repairs Lennox air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.44. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.