Lennox Gas Fireplace: First start-up: pilot slow to light – Lennox Elite LDV
First start-up: pilot slow to light - Lennox Elite LDV on a Lennox gas fireplace: New install, first start, pilot won't catch right away. Usually not a fault. The new gas line is full of air, and the Elite LDV control will keep trying to light until gas reaches the pilot. What I normally find is a couple of failed attempts and then it lights. Let it work through its retries, but stay with it and know when to stop. Gas work is for a licensed fitter.
Applies to: Elite Linear View LDV42N, LDV42P, LDV54N, LDV54P (SIT Proflame DFC control, remote wall receiver)
Common causes of first start-up: pilot slow to light - lennox elite ldv
- Air in the new gas line that has to be purged before gas reaches the pilot
- Gas shutoff not fully open at the fireplace or the supply
- Pilot flame not wrapping the flame sensor rod, so the control drops it
- Leak or restriction in a field joint, found with leak solution
How to fix first start-up: pilot slow to light - lennox elite ldv: step by step
- Safety first: gas work by a licensed gas fitter only. Shut the gas off at the fireplace shutoff before opening any fittings.
- A new gas line is full of air, so the first light-off can take several minutes. Let the control keep retrying.
- Watch that the igniter lights the pilot and the pilot flame wraps around the flame sensor rod.
- Leak test all factory and field joints with leak solution while it runs. Never use a flame.
- If you smell gas at any time, shut it off, ventilate the room and get out.
- If it will not light after purging, turn the gas off and call service.
- Do not keep cycling the control over and over, since that just pushes more unburned gas into the box.
If the unit shows an error code, look it up: Lennox Gas Fireplace codes
Models
Source: Lennox Hearth Elite Linear View Direct-Vent Gas Fireplace LDV42/LDV54 Installation Instructions 506011-02 (06/2012), Verifying Appliance Operation p.30-31; Testing Connections p.12. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.