Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Error Code TEST pins (P1): Defrost control TEST pins (field test jumper) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Lennox error code TEST pins (P1) on a heat pump means: Defrost control TEST pins (field test jumper). It is also called Lennox diagnostic code TEST pins (P1).

Low severityHeat PumpLennox EL16KP1 · Lennox ML14KP1

Homeowner? What Lennox code TEST pins (P1) means for you

Usually minor Your heat pump is reporting: Defrost control TEST pins (field test jumper). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code TEST pins (P1) mean?

A jumper placed on the TEST pins (P1) of the demand defrost control lets the technician clear a short cycle lockout, clear a five-strike fault lockout, and force the unit into and out of defrost to clear the coil. While the TEST jumper is on, the 30 second compressor off-delay around defrost does not work, and the 5-minute anti-short-cycle delay is bypassed.

Applies to: Lennox EL16KP1 (Elite) and ML14KP1 (Merit) R-454B heat pumps, sizes -018 to -060, demand defrost control A108 (CMC1)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code TEST pins (P1)

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Other Lennox Heat Pump codes

CodeMeaning
Green OFF / Red SLOW flashLow pressure fault
Green ON / Red OFFHigh pressure lockout
Green ON / Red ONDemand defrost control failure
Green SLOW flash / Red OFFHigh pressure fault
Green SLOW flash / Red ONDischarge line temperature fault
Red LED on / Green LED offInverter board normal (no fault)

All Lennox Heat Pump error codes →

Lennox code TEST pins (P1): homeowner questions

What does Lennox code TEST pins (P1) mean?

Defrost control TEST pins (field test jumper). A jumper placed on the TEST pins (P1) of the demand defrost control lets the technician clear a short cycle lockout, clear a five-strike fault lockout, and force the unit into and out of defrost to clear the coil. While the TEST jumper is…

Is it safe to keep using my heat pump with code TEST pins (P1)?

Usually yes. Code TEST pins (P1) is normally minor, but if it keeps coming back have it checked.

Can I reset Lennox code TEST pins (P1) myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code TEST pins (P1) comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code TEST pins (P1) near me?

Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Lennox EL16KP1 Unit Information 100195 / ML14KP1 Unit Information 100108, Defrost Control Connections, Test Pins (P1) Function, p.31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977