Lennox Error Code TEST pins (P1): Defrost control TEST pins (field test jumper) (Heat Pump)
Lennox error code TEST pins (P1) on a heat pump means: Defrost control TEST pins (field test jumper). It is also called Lennox diagnostic code TEST pins (P1).
Homeowner? What Lennox code TEST pins (P1) means for you
Usually minor Your heat pump is reporting: Defrost control TEST pins (field test jumper). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Lennox error code TEST pins (P1) mean?
A jumper placed on the TEST pins (P1) of the demand defrost control lets the technician clear a short cycle lockout, clear a five-strike fault lockout, and force the unit into and out of defrost to clear the coil. While the TEST jumper is on, the 30 second compressor off-delay around defrost does not work, and the 5-minute anti-short-cycle delay is bypassed.
Applies to: Lennox EL16KP1 (Elite) and ML14KP1 (Merit) R-454B heat pumps, sizes -018 to -060, demand defrost control A108 (CMC1)
Lennox models that use code TEST pins (P1)
EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060
Other Lennox Heat Pump codes
All Lennox Heat Pump error codes →
Lennox code TEST pins (P1): homeowner questions
What does Lennox code TEST pins (P1) mean?
Defrost control TEST pins (field test jumper). A jumper placed on the TEST pins (P1) of the demand defrost control lets the technician clear a short cycle lockout, clear a five-strike fault lockout, and force the unit into and out of defrost to clear the coil. While the TEST jumper is…
Is it safe to keep using my heat pump with code TEST pins (P1)?
Usually yes. Code TEST pins (P1) is normally minor, but if it keeps coming back have it checked.
Can I reset Lennox code TEST pins (P1) myself?
You can try one reset (power off for 30 seconds, then on). If Lennox code TEST pins (P1) comes back, the cause is still there and a licensed technician should check it.
Who can fix Lennox code TEST pins (P1) near me?
Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Lennox EL16KP1 Unit Information 100195 / ML14KP1 Unit Information 100108, Defrost Control Connections, Test Pins (P1) Function, p.31. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.