Lennox Error Code E446: Low suction pressure fault (AC)

Updated · by Aurora Star Tech Inc.

Lennox error code E446 on a air conditioner means: Low suction pressure fault. It is also called Lennox diagnostic code E446.

High severityAir ConditionerAlso Heat Pump

Homeowner? What Lennox code E446 means for you

Call a technician Your air conditioner is reporting: Low suction pressure fault. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E446 mean?

Suction pressure below 40 psig in operation; escalates to service urgent and stops after five strikes in one demand. S30/S40 thermostat alert code 446 (shown as E446 on the unit control display).

Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code E446

  • Low charge
  • Low indoor airflow
  • Failed low pressure switch
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E446

EL16KC1-018-230AEL16KC1-024-230AEL16KC1-030-230AEL16KC1-036-230AEL16KC1-041-230AEL16KC1-042-230AEL16KC1-047-230AEL16KC1-048-230AEL16KC1-060-230A

Other Lennox AC codes

CodeMeaning
E437Inverter heat-sink temperature sensor fault (inverter code 65)
E438Inverter PFC input over-current (inverter code 73)
E440Inverter compressor slowdown - high heat-sink temperature (inverter code 13)
E441Inverter compressor slowdown - high compressor current (inverter code 14)
E442Compressor top cap switch strikes lockout
E443Unit code to inverter model mismatch
E600Load shed event
E601Low ambient operational lockout

All Lennox Air Conditioner error codes →

Lennox code E446: homeowner questions

What does Lennox code E446 mean?

Low suction pressure fault. Suction pressure below 40 psig in operation; escalates to service urgent and stops after five strikes in one demand. S30/S40 thermostat alert code 446 (shown as E446 on the unit control display).

Is it safe to keep using my air conditioner with code E446?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code E446 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E446 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E446 near me?

Aurora Star Tech Inc. repairs Lennox air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.44. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977