Lennox Error Code 71506: Suction pressure sensor incorrect reading (AC)

Updated · by Aurora Star Tech Inc.

Lennox error code 71506 on a air conditioner means: Suction pressure sensor incorrect reading. It is also called Lennox diagnostic code 71506.

Low severityAir ConditionerAlso Heat Pump

Homeowner? What Lennox code 71506 means for you

Usually minor Your air conditioner is reporting: Suction pressure sensor incorrect reading. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code 71506 mean?

Measured suction pressure (SP) outside expected range; no major system impact. (S40 system diagnostics) S30/S40 thermostat alert code 71506.

Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code 71506

  • See description
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code 71506

EL16KC1-018-230AEL16KC1-024-230AEL16KC1-030-230AEL16KC1-036-230AEL16KC1-041-230AEL16KC1-042-230AEL16KC1-047-230AEL16KC1-048-230AEL16KC1-060-230A

Other Lennox AC codes

CodeMeaning
70502Smart room sensor internal fault
70503Smart room sensor low battery
70504Smart room sensor battery 1%
71001Wireless extender internal data fault
71504Suction temperature sensor incorrect reading
71505Liquid temperature sensor incorrect reading
71507Liquid pressure sensor incorrect reading
71508Outdoor temperature sensor incorrect reading
71510Indoor TXV failure
71512High-pressure switch fault
71513Low-pressure switch fault
71514System low on refrigerant charge

All Lennox Air Conditioner error codes →

Lennox code 71506: homeowner questions

What does Lennox code 71506 mean?

Suction pressure sensor incorrect reading. Measured suction pressure (SP) outside expected range; no major system impact. (S40 system diagnostics) S30/S40 thermostat alert code 71506.

Is it safe to keep using my air conditioner with code 71506?

Usually yes. Code 71506 is normally minor, but if it keeps coming back have it checked.

Can I reset Lennox code 71506 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code 71506 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code 71506 near me?

Aurora Star Tech Inc. repairs Lennox air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.49. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.