Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Error Code E435: Inverter EEPROM checksum fault (inverter code 60) (AC)

Updated · by Aurora Star Tech Inc.

Lennox error code E435 on a air conditioner means: Inverter EEPROM checksum fault (inverter code 60). It is also called Lennox diagnostic code E435.

High severityAir ConditionerAlso Heat Pump

Homeowner? What Lennox code E435 means for you

Call a technician Your air conditioner is reporting: Inverter EEPROM checksum fault (inverter code 60). The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E435 mean?

Inverter internal error; the outdoor control cycles inverter power (contactor open two minutes) three times, then locks out. Inverter LED flash code 60 (red 6 flashes, green off). S30/S40 thermostat alert code 435 (shown as E435 on the unit control display).

Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code E435

  • Inverter internal fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E435

EL16KC1-018-230AEL16KC1-024-230AEL16KC1-030-230AEL16KC1-036-230AEL16KC1-041-230AEL16KC1-042-230AEL16KC1-047-230AEL16KC1-048-230AEL16KC1-060-230A

Other Lennox AC codes

CodeMeaning
E429Inverter DC link low voltage (inverter code 23)
E430Inverter compressor startup fail (inverter code 26)
E431Inverter PFC fault (inverter code 27)
E432Inverter DC link high voltage (inverter code 28)
E433Inverter compressor over-current (inverter code 29)
E434Inverter communication error to main control (inverter code 53)
E436Inverter high heat-sink temperature (inverter code 62)
E437Inverter heat-sink temperature sensor fault (inverter code 65)
E438Inverter PFC input over-current (inverter code 73)
E440Inverter compressor slowdown - high heat-sink temperature (inverter code 13)
E441Inverter compressor slowdown - high compressor current (inverter code 14)
E442Compressor top cap switch strikes lockout

All Lennox Air Conditioner error codes →

Lennox code E435: homeowner questions

What does Lennox code E435 mean?

Inverter EEPROM checksum fault (inverter code 60). Inverter internal error; the outdoor control cycles inverter power (contactor open two minutes) three times, then locks out. Inverter LED flash code 60 (red 6 flashes, green off). S30/S40 thermostat alert code 435 (shown as E435 on the…

Is it safe to keep using my air conditioner with code E435?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code E435 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E435 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E435 near me?

Aurora Star Tech Inc. repairs Lennox air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.