Lennox Error Code LED1 SLOW flash / LED2 FAST flash: Low flame signal (Furnace)
Lennox error code LED1 SLOW flash / LED2 FAST flash on a furnace means: Low flame signal. It is also called Lennox diagnostic code LED1 SLOW flash / LED2 FAST flash.
Homeowner? What Lennox code LED1 SLOW flash / LED2 FAST flash means for you
Check, then call Your furnace is reporting: Low flame signal. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Lennox error code LED1 SLOW flash / LED2 FAST flash mean?
Flame is proven but the signal is weak. Trips below 0.18 microamps on board 32M88, and below 1.5 microamps on boards 78M47 and 100973-01. The furnace still runs. Low flame current is rated at 0.16-0.17 microamps (32M88) or 0.5-1.4 microamps (78M47, 100973-01).
Applies to: G43UF-24B-045 through G43UF-60D-135 (SureLight boards 32M88, 78M47, 100973-01)
Common causes of Lennox code LED1 SLOW flash / LED2 FAST flash
- Flame sensor rod positioned wrong on the burner
- Flame sensor rod dirty or coated
Lennox models that use code LED1 SLOW flash / LED2 FAST flash
G43UF-24B-045G43UF-24B-070G43UF-36B-070G43UF-36C-090G43UF-36C-090HG43UF-48C-090G43UF-48C-110G43UF-48C-110HG43UF-60C-110G43UF-60D-135
Other Lennox Furnace codes
All Lennox Furnace error codes →
Lennox code LED1 SLOW flash / LED2 FAST flash: homeowner questions
What does Lennox code LED1 SLOW flash / LED2 FAST flash mean?
Low flame signal. Flame is proven but the signal is weak. Trips below 0.18 microamps on board 32M88, and below 1.5 microamps on boards 78M47 and 100973-01. The furnace still runs. Low flame current is rated at 0.16-0.17 microamps (32M88) or 0.5-1.4…
Is it safe to keep using my furnace with code LED1 SLOW flash / LED2 FAST flash?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Lennox code LED1 SLOW flash / LED2 FAST flash myself?
You can try one reset (power off for 30 seconds, then on). If Lennox code LED1 SLOW flash / LED2 FAST flash comes back, the cause is still there and a licensed technician should check it.
Who can fix Lennox code LED1 SLOW flash / LED2 FAST flash near me?
Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: Lennox G43UF Unit Information Corp. 0416-L4, Troubleshooting Chart Problem 6 p.55 and Table 4 p.11. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.