Lennox Error Code Green ON / Red OFF: High pressure lockout (Heat Pump)

Updated · by Aurora Star Tech Inc.

Lennox error code Green ON / Red OFF on a heat pump means: High pressure lockout. It is also called Lennox diagnostic code Green ON / Red OFF.

High severityHeat PumpLennox EL16KP1 · Lennox ML14KP1

Homeowner? What Lennox code Green ON / Red OFF means for you

Call a technician Your heat pump is reporting: High pressure lockout. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code Green ON / Red OFF mean?

The high pressure switch tripped 5 times (5 strikes) and the control locked out the compressor.

Applies to: Lennox EL16KP1 (Elite) and ML14KP1 (Merit) R-454B heat pumps, sizes -018 to -060, demand defrost control A108 (CMC1)

Common causes of Lennox code Green ON / Red OFF

  • Restricted airflow over the indoor or outdoor coil (dirty coil, filter, blocked fan)
  • Wrong refrigerant charge
  • Wrong metering device installed or expansion valve not working properly

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code Green ON / Red OFF

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Other Lennox Heat Pump codes

CodeMeaning
Green FAST flash / Red OFFDischarge sensor lockout
Green FAST flash / Red ONDischarge line temperature lockout
Green OFF / Red FAST flashDischarge sensor fault
Green OFF / Red OFFNo power to the demand defrost control
Green OFF / Red ONLow pressure lockout
Green OFF / Red SLOW flashLow pressure fault
Green ON / Red ONDemand defrost control failure
Green SLOW flash / Red OFFHigh pressure fault
Green SLOW flash / Red ONDischarge line temperature fault
Red LED on / Green LED offInverter board normal (no fault)
TEST pins (P1)Defrost control TEST pins (field test jumper)

All Lennox Heat Pump error codes →

Lennox code Green ON / Red OFF: homeowner questions

What does Lennox code Green ON / Red OFF mean?

High pressure lockout. The high pressure switch tripped 5 times (5 strikes) and the control locked out the compressor.

Is it safe to keep using my heat pump with code Green ON / Red OFF?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code Green ON / Red OFF myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code Green ON / Red OFF comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code Green ON / Red OFF near me?

Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Lennox EL16KP1 Unit Information 100195 / ML14KP1 Unit Information 100108, Table 4 Demand Defrost Control (A108) Diagnostic LEDs, p.32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.