Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Error Code E240: Low flame current (run mode) (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code E240 on a furnace means: Low flame current (run mode). It is also called Lennox diagnostic code E240.

Medium severityFurnaceEL296UHV · Lennox SL280UHV · Lennox ML180UHE · Lennox SL297NV

Homeowner? What Lennox code E240 means for you

Check, then call Your furnace is reporting: Low flame current (run mode). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E240 mean?

Flame signal is weak while running.

Applies to: EL296UHV(X) series furnaces (integrated control 103130-XX and 107045-XX)

Common causes of Lennox code E240

  • Dirty or oxidized flame sensor
  • Poor unit ground
  • Burner/flame not contacting sensor
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E240

Show all 34 models

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60DML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DKSL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60DSL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Other Lennox Furnace codes

CodeMeaning
E224Low pressure switch failed closed
E225High pressure switch failed open
E226High pressure switch failed closed
E227Low pressure switch opened during ignition or run
E228Inducer calibration failure
E229Ignition on high fire
E241Flame sensed out of sequence - flame present
E250Limit switch circuit open
E252Discharge air temperature too high
E270Soft lockout - no flame after max retries
E271Soft lockout - retries exceeded, pressure switch opened
E272Soft lockout - recycles exceeded, pressure switch opened

All Lennox Furnace error codes →

Lennox code E240: homeowner questions

What does Lennox code E240 mean?

Low flame current (run mode). Flame signal is weak while running.

Is it safe to keep using my furnace with code E240?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Lennox code E240 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E240 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E240 near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox EL296UHV(X) Unit Information / Service Literature, Table 5 Ignition Control 103130-XX Diagnostic Codes, p.35; Ignition Control 107045-XX Diagnostic Codes table, p.42, Heating System Service Checks p.82-85, Maintenance p.88-89, Unit Components p.52. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977