Lennox Error Code 71510: Indoor TXV failure (AC)

Updated · by Aurora Star Tech Inc.

Lennox error code 71510 on a air conditioner means: Indoor TXV failure. It is also called Lennox diagnostic code 71510.

Medium severityAir ConditionerAlso Heat Pump

Homeowner? What Lennox code 71510 means for you

Check, then call Your air conditioner is reporting: Indoor TXV failure. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code 71510 mean?

Average superheat too high or too low. (S40 system diagnostics) S30/S40 thermostat alert code 71510.

Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code 71510

  • See description
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code 71510

EL16KC1-018-230AEL16KC1-024-230AEL16KC1-030-230AEL16KC1-036-230AEL16KC1-041-230AEL16KC1-042-230AEL16KC1-047-230AEL16KC1-048-230AEL16KC1-060-230A

Other Lennox AC codes

CodeMeaning
71001Wireless extender internal data fault
71504Suction temperature sensor incorrect reading
71505Liquid temperature sensor incorrect reading
71506Suction pressure sensor incorrect reading
71507Liquid pressure sensor incorrect reading
71508Outdoor temperature sensor incorrect reading
71512High-pressure switch fault
71513Low-pressure switch fault
71514System low on refrigerant charge
71516Outdoor fan motor failure
71518Compressor failed to start
71520Blocked liquid line

All Lennox Air Conditioner error codes →

Lennox code 71510: homeowner questions

What does Lennox code 71510 mean?

Indoor TXV failure. Average superheat too high or too low. (S40 system diagnostics) S30/S40 thermostat alert code 71510.

Is it safe to keep using my air conditioner with code 71510?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Lennox code 71510 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code 71510 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code 71510 near me?

Aurora Star Tech Inc. repairs Lennox air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.50. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.