Lennox Error Code 8 flashes: Rollout switch open (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code 8 flashes on a furnace means: Rollout switch open. It is also called Lennox diagnostic code 8 flashes.

Critical severityFurnaceLennox EL195UHNE

Homeowner? What Lennox code 8 flashes means for you

Stop and call Your furnace is reporting: Rollout switch open. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code 8 flashes mean?

The flame rollout switch has opened. Gas is off, inducer and blower run. The sequence holds until the switch is reset and power or thermostat is cycled.

Applies to: EL195UHNE furnaces with ignition control 103217-03 or 107163-01 (red LED)

Common causes of Lennox code 8 flashes

  • Blocked heat exchanger
  • Blocked vent or intake
  • Plugged condensate drain

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code 8 flashes

EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C

Other Lennox Furnace codes

CodeMeaning
1 flashLine voltage polarity reversed
2 flashesImproper earth ground
3 flashesBurner failed to light or lost flame
4 flashesLow flame signal
5 flashesWatchguard - ignition retries/recycles exceeded
7 flashesPrimary or secondary limit open
9 flashesPressure switch stays open or drops out on a heat call
10Unknown device detected
10 flashesWatchguard - pressure switch opened 5 times in one heat demand
11Missing device
11 flashesPressure switch stuck closed before inducer starts
12Indoor unit not detected

All Lennox Furnace error codes →

Lennox code 8 flashes: homeowner questions

What does Lennox code 8 flashes mean?

Rollout switch open. The flame rollout switch has opened. Gas is off, inducer and blower run. The sequence holds until the switch is reset and power or thermostat is cycled.

Is it safe to keep using my furnace with code 8 flashes?

No. Code 8 flashes is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Lennox code 8 flashes myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Lennox code 8 flashes near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox EL195UHNE Unit Information Corp 1801-L1 (rev 04/2024), Table 4 (103217-03) / Table 5 (107163-01) diagnostic codes, p.8-10; flowchart p.51-52. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.