Lennox Error Code E275: Soft lockout – flame out of sequence, now gone (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code E275 on a furnace means: Soft lockout - flame out of sequence, now gone. It is also called Lennox diagnostic code E275.

Critical severityFurnaceEL296UHV · Lennox SL280UHV · Lennox ML180UHE · Lennox SL297NV

Homeowner? What Lennox code E275 means for you

Stop and call Your furnace is reporting: Soft lockout - flame out of sequence, now gone. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E275 mean?

Flame was sensed out of sequence and is now gone. 1-hour soft lockout.

Applies to: EL296UHV(X) series furnaces (integrated control 103130-XX and 107045-XX)

Common causes of Lennox code E275

  • Gas valve leaking through
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E275

Show all 34 models

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60DML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DKSL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60DSL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Other Lennox Furnace codes

CodeMeaning
E252Discharge air temperature too high
E270Soft lockout - no flame after max retries
E271Soft lockout - retries exceeded, pressure switch opened
E272Soft lockout - recycles exceeded, pressure switch opened
E273Soft lockout - recycles exceeded, flame failure
E274Soft lockout - limit opened
E276Watchguard calibration failure
E290Ignitor circuit fault
E291Heat airflow below minimum
E292Blower motor will not start
E294Inducer over current
E295Blower motor over temperature

All Lennox Furnace error codes →

Lennox code E275: homeowner questions

What does Lennox code E275 mean?

Soft lockout - flame out of sequence, now gone. Flame was sensed out of sequence and is now gone. 1-hour soft lockout.

Is it safe to keep using my furnace with code E275?

No. Code E275 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Lennox code E275 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Lennox code E275 near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox EL296UHV(X) Unit Information / Service Literature, Table 5 Ignition Control 103130-XX Diagnostic Codes, p.36; Ignition Control 107045-XX Diagnostic Codes table, p.43, Start-Up / Gas Valve Operation p.81. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977